At a glance
Gauge pressure measurement ranges from 0 ... 0.1 bar up to 0 … 600 bar |
Process temperature up to 125 °C (optional) |
High shock and vibration resistance |
Accuracy 0.5% or 0.25% |
Output signal 4 … 20 mA, 0 … 5 V, or 0 … 10 V |
Zero and span adjustable |
Electrical connection M12x1, L-connector according to DIN 175301-803 A or flying leads |
Your benefits
Reliable and highly accurate measurement technology |
Wide application range |
No mechanical wear, fatigue-proof, maintenance-free as no moving parts |
Simple and cost-saving installation |
Optimal solution for individual requirements due to very versatile configurability |
Maximum installation flexibility due to availability of a large range of customary thread types |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 psi ... 200 psi | ||
Температура процесса: | -30 °C ... 100 °C | ||
CE-conformity: | |||
Output signal: | 0...5 V, 3-wire |
Performance | |||
Accuracy: | |||
Non-linearity: | |||
Long-term drift/one-year stability: | |||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.2 % of span / 10 K ( | ||
Rated temperature range: | 0 °C ... 80 °C | ||
Non-repeatability: | |||
Response time (10 % ... 90 %): | ≤ 1 ms (≤ 10 ms at medium temperatures below |
Механика/электроника | |||
Process connection: | G 1/4 A according to DIN 3852-E | ||
Детали, контактирующие с измеряемой средой: | Standard: Stainless steel | ||
Seal: | Without seal | ||
Pressure port: | Standard | ||
Материал корпуса: | Stainless steel | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | M12 x 1, 4-pin, IP 67 | ||
Supply voltage: | 10 V DC ... 30 V DC | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | 200 g | ||
CE-conformity: | Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... 100 °C | ||
Ambient temperature: | -20 °C ... 80 °C | ||
Shock load: | 1000 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 20 g according to IEC 60068-2-6 (vibration under resonance) |
At a glance
Gauge pressure measurement ranges from 0 ... 0.1 bar up to 0 … 600 bar |
Process temperature up to 125 °C (optional) |
High shock and vibration resistance |
Accuracy 0.5% or 0.25% |
Output signal 4 … 20 mA, 0 … 5 V, or 0 … 10 V |
Zero and span adjustable |
Electrical connection M12x1, L-connector according to DIN 175301-803 A or flying leads |
Your benefits
Reliable and highly accurate measurement technology |
Wide application range |
No mechanical wear, fatigue-proof, maintenance-free as no moving parts |
Simple and cost-saving installation |
Optimal solution for individual requirements due to very versatile configurability |
Maximum installation flexibility due to availability of a large range of customary thread types |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 psi ... 500 psi | ||
Температура процесса: | -30 °C ... 100 °C | ||
CE-conformity: | |||
Output signal: | 0...10 V, 3-wire |
Performance | |||
Accuracy: | |||
Non-linearity: | |||
Long-term drift/one-year stability: | |||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.2 % of span / 10 K ( | ||
Rated temperature range: | 0 °C ... 80 °C | ||
Non-repeatability: | |||
Response time (10 % ... 90 %): | ≤ 1 ms (≤ 10 ms at medium temperatures below |
Механика/электроника | |||
Process connection: | 1/4'' NPT | ||
Детали, контактирующие с измеряемой средой: | Standard: Stainless steel | ||
Seal: | Without seal | ||
Pressure port: | Standard | ||
Материал корпуса: | Stainless steel | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | M12 x 1, 4-pin, IP 67 | ||
Supply voltage: | 10 V DC ... 30 V DC | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | 200 g | ||
CE-conformity: | Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... 100 °C | ||
Ambient temperature: | -20 °C ... 80 °C | ||
Shock load: | 1000 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 20 g according to IEC 60068-2-6 (vibration under resonance) |
At a glance
Gauge pressure measurement ranges from 0 ... 0.1 bar up to 0 … 600 bar |
Process temperature up to 125 °C (optional) |
High shock and vibration resistance |
Accuracy 0.5% or 0.25% |
Output signal 4 … 20 mA, 0 … 5 V, or 0 … 10 V |
Zero and span adjustable |
Electrical connection M12x1, L-connector according to DIN 175301-803 A or flying leads |
Your benefits
Reliable and highly accurate measurement technology |
Wide application range |
No mechanical wear, fatigue-proof, maintenance-free as no moving parts |
Simple and cost-saving installation |
Optimal solution for individual requirements due to very versatile configurability |
Maximum installation flexibility due to availability of a large range of customary thread types |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 psi ... 8,000 psi | ||
Температура процесса: | -40 °C ... 125 °C | ||
CE-conformity: | |||
Output signal: | 4...20 mA |
Performance | |||
Accuracy: | |||
Non-linearity: | |||
Long-term drift/one-year stability: | |||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.2 % of span / 10 K ( | ||
Rated temperature range: | 0 °C ... 80 °C | ||
Non-repeatability: | |||
Response time (10 % ... 90 %): | ≤ 1 ms (≤ 10 ms at medium temperatures below |
Механика/электроника | |||
Process connection: | 1/4'' NPT | ||
Детали, контактирующие с измеряемой средой: | Standard: Stainless steel | ||
Seal: | Without seal | ||
Pressure port: | Standard | ||
Материал корпуса: | Stainless steel | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | L-connector acc. to DIN 175301-803 A, IP 65 | ||
Supply voltage: | 10 V DC ... 30 V DC | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | 200 g | ||
CE-conformity: | Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... 100 °C | ||
Ambient temperature: | -20 °C ... 80 °C | ||
Shock load: | 1000 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 20 g according to IEC 60068-2-6 (vibration under resonance) |
At a glance
Gauge pressure measurement ranges from 0 ... 0.1 bar up to 0 … 600 bar |
Process temperature up to 125 °C (optional) |
High shock and vibration resistance |
Accuracy 0.5% or 0.25% |
Output signal 4 … 20 mA, 0 … 5 V, or 0 … 10 V |
Zero and span adjustable |
Electrical connection M12x1, L-connector according to DIN 175301-803 A or flying leads |
Your benefits
Reliable and highly accurate measurement technology |
Wide application range |
No mechanical wear, fatigue-proof, maintenance-free as no moving parts |
Simple and cost-saving installation |
Optimal solution for individual requirements due to very versatile configurability |
Maximum installation flexibility due to availability of a large range of customary thread types |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 psi ... 8,000 psi | ||
Температура процесса: | -40 °C ... 125 °C | ||
CE-conformity: | |||
Output signal: | 4...20 mA |
Performance | |||
Accuracy: | |||
Non-linearity: | |||
Long-term drift/one-year stability: | |||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.2 % of span / 10 K ( | ||
Rated temperature range: | 0 °C ... 80 °C | ||
Non-repeatability: | |||
Response time (10 % ... 90 %): | ≤ 1 ms (≤ 10 ms at medium temperatures below |
Механика/электроника | |||
Process connection: | 1/4'' NPT | ||
Детали, контактирующие с измеряемой средой: | Standard: Stainless steel | ||
Seal: | Without seal | ||
Pressure port: | Standard | ||
Материал корпуса: | Stainless steel | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | L-connector acc. to DIN 175301-803 A, IP 65 | ||
Supply voltage: | 10 V DC ... 30 V DC | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | 200 g | ||
CE-conformity: | Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... 100 °C | ||
Ambient temperature: | -20 °C ... 80 °C | ||
Shock load: | 1000 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 20 g according to IEC 60068-2-6 (vibration under resonance) |
At a glance
Gauge pressure measurement ranges from 0 ... 0.1 bar up to 0 … 600 bar |
Process temperature up to 125 °C (optional) |
High shock and vibration resistance |
Accuracy 0.5% or 0.25% |
Output signal 4 … 20 mA, 0 … 5 V, or 0 … 10 V |
Zero and span adjustable |
Electrical connection M12x1, L-connector according to DIN 175301-803 A or flying leads |
Your benefits
Reliable and highly accurate measurement technology |
Wide application range |
No mechanical wear, fatigue-proof, maintenance-free as no moving parts |
Simple and cost-saving installation |
Optimal solution for individual requirements due to very versatile configurability |
Maximum installation flexibility due to availability of a large range of customary thread types |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 psi ... 8,000 psi | ||
Температура процесса: | -30 °C ... 100 °C | ||
CE-conformity: | |||
Output signal: | 4...20 mA |
Performance | |||
Accuracy: | |||
Non-linearity: | |||
Long-term drift/one-year stability: | |||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.2 % of span / 10 K ( | ||
Rated temperature range: | 0 °C ... 80 °C | ||
Non-repeatability: | |||
Response time (10 % ... 90 %): | ≤ 1 ms (≤ 10 ms at medium temperatures below |
Механика/электроника | |||
Process connection: | 1/4'' NPT | ||
Детали, контактирующие с измеряемой средой: | Standard: Stainless steel | ||
Seal: | Without seal | ||
Pressure port: | Standard | ||
Материал корпуса: | Stainless steel | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | M12 x 1, 4-pin, IP 67 | ||
Supply voltage: | 10 V DC ... 30 V DC | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | 200 g | ||
CE-conformity: | Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... 100 °C | ||
Ambient temperature: | -20 °C ... 80 °C | ||
Shock load: | 1000 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 20 g according to IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Compound pressure measuring ranges from -1 ... 0 bar up to -1 … +15 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Compound pressure | ||
Measuring range: | -1 bar ... 0 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Tri-Clamp 1 ½'' | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Compound pressure measuring ranges from -1 ... 0 bar up to -1 … +15 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Compound pressure | ||
Measuring range: | -1 bar ... 3 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,25 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Varivent Connector Type N | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Field housing IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Compound pressure measuring ranges from -1 ... 0 bar up to -1 … +15 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Compound pressure | ||
Measuring range: | -1 bar ... 3 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Varivent Connector Type N | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Field housing IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 10 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,25 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Conical coupling (DIN 11851) DN 50 with union nut | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Field housing IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 10 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,25 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Varivent Connector Type N | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Field housing IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 10 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | SMS-Standard 1½'' mit Nutüberwurfmutter | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Field housing IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 10 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | tri-clamp 2" | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Field housing IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 10 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | tri-clamp 2" | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 10 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Varivent Connector Type N | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Field housing IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 16 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Clamp (DIN 32676) DN 40 | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 1 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | DRD Connector with clamping elements | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 1 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 0...10 V, 3-wire | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Tri-Clamp 1 ½'' | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Field housing IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 1.6 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,25 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Tri-Clamp 1 ½'' | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 2.5 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Flange (DIN 11864-2) DN 40 form A | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 2.5 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | DRD Connector with clamping elements | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 2.5 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 0...10 V, 3-wire | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Tri-Clamp 1 ½'' | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Field housing IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 4 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Conical coupling (DIN 11851) DN 40 with union nut | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 6 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,25 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Tri-Clamp 1 ½'' | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 65 | ||
Тип подключения: | Winkelstecker (DIN EN 175301-803 A), IP 65 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 6 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,25 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Varivent Connector Type N | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Field housing IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 6 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Clamp (DIN 11864-3) DNÂ 40 form A | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 6 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | SMS-Standard 1½'' mit Nutüberwurfmutter | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 6 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 0...10 V, 3-wire | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Tri-Clamp 1 ½'' | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 6 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Varivent Connector Type N | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Field housing IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 0.25 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Conical coupling (DIN 11851) DN 25 with union nut | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 65 | ||
Тип подключения: | Winkelstecker (DIN EN 175301-803 A), IP 65 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 0.25 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Tri-Clamp 1 ½'' | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 65 | ||
Тип подключения: | Winkelstecker (DIN EN 175301-803 A), IP 65 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 0.4 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Conical coupling (DIN 11851) DN 50 with union nut | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 65 | ||
Тип подключения: | Winkelstecker (DIN EN 175301-803 A), IP 65 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 0.4 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Tri-Clamp 1 ½'' | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | Without seal | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 65 | ||
Тип подключения: | Winkelstecker (DIN EN 175301-803 A), IP 65 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 0.6 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,25 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Tri-Clamp 1 ½'' | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 67 | ||
Тип подключения: | Round connector M12 x 1, 4-pin, IP 67 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
At a glance
Robust and precise pressure measurement technology |
Gauge measuring ranges from 0 ... 0.25 bar up to 0 … 25 bar |
Available in 2 accuracy classes: |
Flush-mounted, hermetically sealed stainless steel membrane with roughness Ra |
Wetted parts stainless steel 1.4435, housing stainless steel 1.4571 |
Large range of hygienic process connectors |
Stainless steel housing and field housing with enclosure rating of up to IP 68 |
Your benefits
Perfectly suited for demanding hygienic applications in the food and beverage, pharmaceutical and cosmetics industries |
Safe hygienic operation through EHEDG and 3-A certifications |
High reliability due to robust design and use of high-grade materials |
Withstands CIP/SIP, ensuring high system availability and reliability |
Transmitter housing is easily cleaned |
Versatile configurability optimizes solutions |
Features | |||
Pressure type: | Gauge pressure | ||
Measuring range: | 0 bar ... 0.6 bar | ||
Температура процесса: | -20 °C ... +150 °C | ||
Output signal: | 4 mA ... 20 mA | ||
Средний: | Liquid and gaseous media | ||
EHEDG approval: |
Performance | |||
Accuracy: | ≤ ± 0,5 % der Spanne optional ≤ ± 0,25 % d. Spanne (kalibriert bei senkrechter Einbaulage, Druckanschluss unten) | ||
Non-linearity: | ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) | ||
Long-term drift/one-year stability: | ≤ 0.2 % of span | ||
Номинальный температурный коэффициент в диапазоне температур: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 % of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mittlerer TK des Nullpunkts: ≤ 0,2 % der Spanne/ 10 K für Messbereiche 0 bar ... 0,6 bar bis 0 bar ... 25 bar, Mittlerer TK des Nullpunkts: ≤ 0,4 % der Spanne/ 10 K für Messbereich 0 bar ... 0,25 bar | ||
Rated temperature range: | 0 °C ... +80 °C | ||
Non-repeatability: | ≤ ± 0.1 % of span | ||
Response time (10 % ... 90 %): | ≤ 10 ms |
Механика/электроника | |||
Process connection: | Conical coupling (DIN 11851) DN 25 with union nut | ||
Детали, контактирующие с измеряемой средой: | Edelstahl 1.4435 | ||
Seal: | EPDM | ||
Материал корпуса: | Stainless steel 1.4571 | ||
Enclosure rating: | IP 65 | ||
Тип подключения: | Winkelstecker (DIN EN 175301-803 A), IP 65 | ||
Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M | ||
Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) | ||
Protection class III: | |||
Weight sensor: | Ca. 500 g | ||
Internal transmission fluid: | Synthetisches Öl, FDA konform | ||
CE-conformity: | EMC directive: 2004/108/EC, EN 61326-2-3 |
Данные окуражающей среды | |||
Storage temperature: | -40 °C ... +100 °C | ||
Ambient temperature: | -20 °C ... +80 °C | ||
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) | ||
Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |