+7 (812) 432-38-38
+7 (812) 432-36-36
Пн-Пт 9:00 — 18:00
 
Заказать оборудование
 

C4000 ATEX II 3G/3D based on C4000 Advanced

 
 
Арт. 1053722

At a glance

  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • ATEX II 3G/3D (2/22 zones)
  • Labelling Gas: Ex nA op is IIC T4 0°C
  • Labelling Dust: Ex tD A22 IP65 T123°C X
  • 7-segment display
  • External device monitoring (EDM) and restart interlock (RES)
  • Beam coding for correct system allocation
  • Configuration and diagnostics via PC

    Your benefits

  • ATEX II 3G/3D for use in 2/22 zones
  • Large scanning ranges up to 19 m and sufficient power reserve for use in paint finishing lines, for example
  • 7-segment display saves time during alignment and diagnostics
  • Beam coding protects the systems against opticalinterference by ensuring a high level of availability
  • Preconfigured light curtains and the clone plug enables easy and rapid commissioning
  • Precise, convenient configuration and diagnostics reduces downtime
    Technical Data-Sender
    Protective field height: 900 mm
    Resolution: 20 mm
    Диапазон сканирования от ... до: 0 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Длина волны: 950 nm
    Класс защиты: III
    Enclosure rating: IP 65
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
    Technical Data-Receiver
    Protective field height: 900 mm
    Resolution: 20 mm
    Диапазон сканирования от ... до: 0 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Длина волны: 950 nm
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Класс защиты: III
    Enclosure rating: IP 65
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
     
    Арт. 1054691

    At a glance

  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • ATEX II 3G/3D (2/22 zones)
  • Labelling Gas: Ex nA op is IIC T4 0°C
  • Labelling Dust: Ex tD A22 IP65 T123°C X
  • 7-segment display
  • External device monitoring (EDM) and restart interlock (RES)
  • Beam coding for correct system allocation
  • Configuration and diagnostics via PC

    Your benefits

  • ATEX II 3G/3D for use in 2/22 zones
  • Large scanning ranges up to 19 m and sufficient power reserve for use in paint finishing lines, for example
  • 7-segment display saves time during alignment and diagnostics
  • Beam coding protects the systems against opticalinterference by ensuring a high level of availability
  • Preconfigured light curtains and the clone plug enables easy and rapid commissioning
  • Precise, convenient configuration and diagnostics reduces downtime
    Technical Data-Sender
    Protective field height: 1,050 mm
    Resolution: 20 mm
    Диапазон сканирования от ... до: 1.5 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Длина волны: 950 nm
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
    Technical Data-Receiver
    Protective field height: 1,050 mm
    Resolution: 20 mm
    Диапазон сканирования от ... до: 1.5 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Длина волны: 950 nm
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
     
    Арт. 1056824

    At a glance

  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • ATEX II 3G/3D (2/22 zones)
  • Labelling Gas: Ex nA op is IIC T4 0°C
  • Labelling Dust: Ex tD A22 IP65 T123°C X
  • 7-segment display
  • External device monitoring (EDM) and restart interlock (RES)
  • Beam coding for correct system allocation
  • Configuration and diagnostics via PC

    Your benefits

  • ATEX II 3G/3D for use in 2/22 zones
  • Large scanning ranges up to 19 m and sufficient power reserve for use in paint finishing lines, for example
  • 7-segment display saves time during alignment and diagnostics
  • Beam coding protects the systems against opticalinterference by ensuring a high level of availability
  • Preconfigured light curtains and the clone plug enables easy and rapid commissioning
  • Precise, convenient configuration and diagnostics reduces downtime
    Functions-Sender
    Кодирование лучей:
    Метод конфигурации: PC with CDS (Configuration and Diagnostic Software)
    Safe SICK device communication via EFI/SDL:
    Functions-Receiver
    Блокировка перезапуска:
    External device monitoring (EDM):
    Кодирование лучей:
    Метод конфигурации: PC with CDS (Configuration and Diagnostic Software)
    Safe SICK device communication via EFI/SDL:
    Technical Data-Sender
    Protective field height: 1,350 mm
    Resolution: 40 mm
    Диапазон сканирования от ... до: 0 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Длина волны: 950 nm
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
    Вес: 2,820 g
    Technical Data-Receiver
    Protective field height: 1,350 mm
    Resolution: 40 mm
    Диапазон сканирования от ... до: 0 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Длина волны: 950 nm
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
     
    Арт. 1063411

    At a glance

  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • ATEX II 3G/3D (2/22 zones)
  • Labelling Gas: Ex nA op is IIC T4 0°C
  • Labelling Dust: Ex tD A22 IP65 T123°C X
  • 7-segment display
  • External device monitoring (EDM) and restart interlock (RES)
  • Beam coding for correct system allocation
  • Configuration and diagnostics via PC

    Your benefits

  • ATEX II 3G/3D for use in 2/22 zones
  • Large scanning ranges up to 19 m and sufficient power reserve for use in paint finishing lines, for example
  • 7-segment display saves time during alignment and diagnostics
  • Beam coding protects the systems against opticalinterference by ensuring a high level of availability
  • Preconfigured light curtains and the clone plug enables easy and rapid commissioning
  • Precise, convenient configuration and diagnostics reduces downtime
    Technical Data-Sender
    Protective field height: 1,800 mm
    Resolution: 20 mm
    Диапазон сканирования от ... до: 1.5 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Длина волны: 950 nm
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
    Technical Data-Receiver
    Protective field height: 1,800 mm
    Resolution: 20 mm
    Диапазон сканирования от ... до: 1.5 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Длина волны: 950 nm
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
     
    Арт. 1063413

    At a glance

  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • ATEX II 3G/3D (2/22 zones)
  • Labelling Gas: Ex nA op is IIC T4 0°C
  • Labelling Dust: Ex tD A22 IP65 T123°C X
  • 7-segment display
  • External device monitoring (EDM) and restart interlock (RES)
  • Beam coding for correct system allocation
  • Configuration and diagnostics via PC

    Your benefits

  • ATEX II 3G/3D for use in 2/22 zones
  • Large scanning ranges up to 19 m and sufficient power reserve for use in paint finishing lines, for example
  • 7-segment display saves time during alignment and diagnostics
  • Beam coding protects the systems against opticalinterference by ensuring a high level of availability
  • Preconfigured light curtains and the clone plug enables easy and rapid commissioning
  • Precise, convenient configuration and diagnostics reduces downtime
    Functions-Sender
    Кодирование лучей:
    Метод конфигурации: PC with CDS (Configuration and Diagnostic Software)
    Safe SICK device communication via EFI/SDL:
    Functions-Receiver
    Блокировка перезапуска:
    External device monitoring (EDM):
    Кодирование лучей:
    Метод конфигурации: PC with CDS (Configuration and Diagnostic Software)
    Safe SICK device communication via EFI/SDL:
    Technical Data-Sender
    Protective field height: 1,800 mm
    Resolution: 14 mm
    Диапазон сканирования от ... до: 0 m ... 8 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Длина волны: 950 nm
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
    Technical Data-Receiver
    Protective field height: 1,800 mm
    Resolution: 14 mm
    Диапазон сканирования от ... до: 0 m ... 8 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Длина волны: 950 nm
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
     
    Арт. 1064892

    At a glance

  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • ATEX II 3G/3D (2/22 zones)
  • Labelling Gas: Ex nA op is IIC T4 0°C
  • Labelling Dust: Ex tD A22 IP65 T123°C X
  • 7-segment display
  • External device monitoring (EDM) and restart interlock (RES)
  • Beam coding for correct system allocation
  • Configuration and diagnostics via PC

    Your benefits

  • ATEX II 3G/3D for use in 2/22 zones
  • Large scanning ranges up to 19 m and sufficient power reserve for use in paint finishing lines, for example
  • 7-segment display saves time during alignment and diagnostics
  • Beam coding protects the systems against opticalinterference by ensuring a high level of availability
  • Preconfigured light curtains and the clone plug enables easy and rapid commissioning
  • Precise, convenient configuration and diagnostics reduces downtime
    Functions-Sender
    Кодирование лучей:
    Метод конфигурации: PC with CDS (Configuration and Diagnostic Software)
    Safe SICK device communication via EFI/SDL:
    Functions-Receiver
    Блокировка перезапуска:
    External device monitoring (EDM):
    Кодирование лучей:
    Метод конфигурации: PC with CDS (Configuration and Diagnostic Software)
    Safe SICK device communication via EFI/SDL:
    Technical Data-Sender
    Protective field height: 1,500 mm
    Resolution: 30 mm
    Диапазон сканирования от ... до: 0 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Длина волны: 950 nm
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
    Вес: 3,110 g
    Technical Data-Receiver
    Protective field height: 1,500 mm
    Resolution: 30 mm
    Диапазон сканирования от ... до: 0 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Длина волны: 950 nm
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
     
    Арт. 1065841

    At a glance

  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • ATEX II 3G/3D (2/22 zones)
  • Labelling Gas: Ex nA op is IIC T4 0°C
  • Labelling Dust: Ex tD A22 IP65 T123°C X
  • 7-segment display
  • External device monitoring (EDM) and restart interlock (RES)
  • Beam coding for correct system allocation
  • Configuration and diagnostics via PC

    Your benefits

  • ATEX II 3G/3D for use in 2/22 zones
  • Large scanning ranges up to 19 m and sufficient power reserve for use in paint finishing lines, for example
  • 7-segment display saves time during alignment and diagnostics
  • Beam coding protects the systems against opticalinterference by ensuring a high level of availability
  • Preconfigured light curtains and the clone plug enables easy and rapid commissioning
  • Precise, convenient configuration and diagnostics reduces downtime
    Technical Data-Sender
    Protective field height: 600 mm
    Resolution: 20 mm
    Диапазон сканирования от ... до: 1.5 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Длина волны: 950 nm
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
    Technical Data-Receiver
    Protective field height: 600 mm
    Resolution: 20 mm
    Диапазон сканирования от ... до: 1.5 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Длина волны: 950 nm
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
     
    Арт. 1070016

    At a glance

  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • ATEX II 3G/3D (2/22 zones)
  • Labelling Gas: Ex nA op is IIC T4 0°C
  • Labelling Dust: Ex tD A22 IP65 T123°C X
  • 7-segment display
  • External device monitoring (EDM) and restart interlock (RES)
  • Beam coding for correct system allocation
  • Configuration and diagnostics via PC

    Your benefits

  • ATEX II 3G/3D for use in 2/22 zones
  • Large scanning ranges up to 19 m and sufficient power reserve for use in paint finishing lines, for example
  • 7-segment display saves time during alignment and diagnostics
  • Beam coding protects the systems against opticalinterference by ensuring a high level of availability
  • Preconfigured light curtains and the clone plug enables easy and rapid commissioning
  • Precise, convenient configuration and diagnostics reduces downtime
    Functions-Sender
    Кодирование лучей:
    Метод конфигурации: PC with CDS (Configuration and Diagnostic Software)
    Safe SICK device communication via EFI/SDL:
    Functions-Receiver
    Блокировка перезапуска:
    External device monitoring (EDM):
    Кодирование лучей:
    Метод конфигурации: PC with CDS (Configuration and Diagnostic Software)
    Safe SICK device communication via EFI/SDL:
    Technical Data-Sender
    Protective field height: 1,800 mm
    Resolution: 30 mm
    Диапазон сканирования от ... до: 0 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Длина волны: 950 nm
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
    Вес: 3,680 g
    Technical Data-Receiver
    Protective field height: 1,800 mm
    Resolution: 30 mm
    Диапазон сканирования от ... до: 0 m ... 19 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Длина волны: 950 nm
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
     
    Арт. 1071159

    At a glance

  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • ATEX II 3G/3D (2/22 zones)
  • Labelling Gas: Ex nA op is IIC T4 0°C
  • Labelling Dust: Ex tD A22 IP65 T123°C X
  • 7-segment display
  • External device monitoring (EDM) and restart interlock (RES)
  • Beam coding for correct system allocation
  • Configuration and diagnostics via PC

    Your benefits

  • ATEX II 3G/3D for use in 2/22 zones
  • Large scanning ranges up to 19 m and sufficient power reserve for use in paint finishing lines, for example
  • 7-segment display saves time during alignment and diagnostics
  • Beam coding protects the systems against opticalinterference by ensuring a high level of availability
  • Preconfigured light curtains and the clone plug enables easy and rapid commissioning
  • Precise, convenient configuration and diagnostics reduces downtime
    Functions-Sender
    Кодирование лучей:
    Метод конфигурации: PC with CDS (Configuration and Diagnostic Software)
    Safe SICK device communication via EFI/SDL:
    Functions-Receiver
    Блокировка перезапуска:
    External device monitoring (EDM):
    Кодирование лучей:
    Метод конфигурации: PC with CDS (Configuration and Diagnostic Software)
    Safe SICK device communication via EFI/SDL:
    Technical Data-Sender
    Protective field height: 450 mm
    Resolution: 14 mm
    Диапазон сканирования от ... до: 0 m ... 8 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Длина волны: 950 nm
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
    Technical Data-Receiver
    Protective field height: 450 mm
    Resolution: 14 mm
    Диапазон сканирования от ... до: 0 m ... 8 m
    Type: Type 4 (IEC 61496)
    Category: category 4 (EN ISO 13849)
    Уровень производительности: EN ISO 13849
    TM (mission time): 20 a
    Supply voltage typical, from, to: 24 V DC, 19.2 V DC, 28.8 V DC
    Длина волны: 950 nm
    Тип подключения: Hirschmann male connector M26, 12-pin
    Connection type configuration connection: female connector M8, 4-pin
    Класс защиты: III
    Enclosure rating: IP 65 (EN 60529)
    Vibration resistance (checked to): 5 g (IEC 60068-2-6)
    Частота колебаний от ... до: 10 Hz ... 55 Hz
    Ударопрочность: 16 g (IEC 60068-2-29)
     
     

     
     
     
    Имя Отчество:
     
    Адрес электронной почты:
     
    Контактный телефон:
     
    Наименование компании:
     
    Содержание заказа: