At a glance
Motor feedback system with HIPERFACE DSL® interface |
Compact, robust design with 36 mm diameter |
Up to 20 bit resolution per revolution and 4,096 revolutions measurable with the multiturn system |
Facility for connecting an external temperature sensor |
E²Prom with 8 kbyte of free memory space |
SIL2-certified (only valid for EKS/EKM36-2...) |
Service life histogram |
Your benefits
Saving all analog components on the controller part through exclusively digital data transmission |
Enormous cost saving thanks to the separate encoder cable no longer being necessary, data transmitted synchronously to the controller cycle |
Minimal cabling thanks to integration of the encoder communication into the motor cable |
Optimization of the controller circuit via automatic synchronization with the controller cycle |
Performance | |||
Number of the absolute ascertainable revolutions: | Singleturn | ||
Available memory area: | 8,192 Byte 1) |
Mechanical data | |||
Тип фланца/муфты статора: | Spring mounting plate, Ø 36 | ||
Moment of inertia of the rotor: | 4.5 gcm² | ||
Момент вращения: | 0.2 Ncm | ||
Крутящий момент на старте: | 0.3 Ncm | ||
Допустимое перемещение вала, радиальное статические: | ± 0.1 mm | ||
Допустимое перемещение вала, радиальное, динамическое: | ± 0.05 mm | ||
Допустимое перемещение вала, аксиальное, статическое: | ± 0.5 mm | ||
Permissible shaft movement, axial, dynamic: | ± 0.1 mm | ||
Maximum operating speed: | 12,000 U/min |
Electrical data | |||
Electrical interface: | HIPERFACE DSL |
Данные окуражающей среды | |||
Working temperature range: | -20 °C ... 115 °C | ||
Storage temperature range: | -40 °C ... 125 °C | ||
Относительная влажность / конденсат: | Condensation not permitted | ||
Устойчивость к ударам: | 100 g (IEC 60068-2-27) | ||
Resistance to vibration: | 50 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) | ||
Enclosure rating: | IP 40 |