At a glance
Mounting on integrated profiles with rod diameters up to 14 mm |
NAMUR according to EN 60 947-5-6 |
IP 67 enclosure rating |
Industrial aluminum housing with integrated mounting claw |
Classification TÃœV 99 ATEX 1398 EX II 2 G Ex ia IIC T6 Ta |
LED status indicator |
Operating temperature range from -20...70° C |
Your benefits
Simple and direct mounting onto integrated profile cylinders - saves installation time |
Highly resistant to shock and vibrations, ensuring a long service life and reduced maintenance costs |
High switching point accuracy reduces material loss |
Features | |||
Switching frequency, typ.: | 5,000 Hz | ||
Output type: | NAMUR | ||
Electrical wiring: | DC 2-wire | ||
Sensing face: | Front | ||
Cylinder type: | Profile cylinder | ||
Длина корпуса: | 30 mm | ||
Enclosure rating: | IP 67 1) |
Механика/электроника | |||
Тип подключения: | Cable, 2-wire, 2 m | ||
Supply voltage: | 5 V DC ... 25 V DC | ||
Hysteresis: | ≤ 1 mm | ||
EMC: | According to EN 60947-5-6 | ||
Материал кабеля: | PVC | ||
Сечение провода: | 0.34 mm² | ||
Защита от обратной полярности: | |||
защита от короткого замыкания: | |||
Материал корпуса: | Metal, Aluminum | ||
Sensing face material: | Plastic | ||
Device labeling: | II 2 G Ex ia IIC T6 Ta: -20 °C ... +70 °C | ||
Time delay before availability: | ≤ 2 ms | ||
Magnetic field sensitivity, min.: | 3 mT | ||
Повторяемость: | ≤ 0.1 mm 1) | ||
Ударная и вибрационная устойчивость: | 30 g, 11 ms / 10 ... 55 Hz, 1 mm | ||
Ambient operating temperature: | -25 °C ... 70 °C |