At a glance
Efficient solution to power and connect to SICK’s Auto-ID component portfolio |
Slots for optional fieldbus modules, parameter memory, display and power supply module |
Simple voltage supply of scanner |
IP 65 connection of a scanner using SICK standard cable |
Direct access to the service interface of the sensor |
Connection diagram integrated in lid |
Clearly visible and easily accessible screw/spring-loaded terminals |
Your benefits
Easy connection of the sensor to fieldbus systems |
Fast exchange of the sensor through parameter memory CMC |
Fast installation and easy networking save time |
Simple troubleshooting |
Easy diagnosis via optional CMD400 display module |
Features | |||
Краткое описание: | Modular connection module for one sensor | ||
Поддерживаемые продукты: | CLV42x, CLV43x, CLV44x, CLV45x, CLV62x, CLV63x, CLV64x, CLV65x, ICR84x-2, ICR85x-2, IDM12x, IDM14x, IDM16x, IDM24x, IDM26x, Lector®62x, RFH620 | ||
Supports cloning module (CMC): | Yes | ||
Supports display module (CMD): | Yes | ||
Supports power supply module (CMP): | Yes | ||
Supports fieldbus gateway (CMF): | Yes (PROFIBUS DP, Ethernet, DeviceNet) |
Interfaces | |||
Serial (RS-232, RS-422/485): | |||
Remark (Serial (RS-232, RS-422/485)): | Depending on sensor connected | ||
Ethernet: | |||
Remark (Ethernet): | Depending on Sensor connected; corresponding CMF fieldbus gateway additionally necessary | ||
CAN bus: | |||
Remark (CAN bus): | Depending on sensor connected | ||
PROFIBUS DP: | |||
DeviceNet: | |||
Remark (DeviceNet): | Corresponding CMF fieldbus gateway additionally necessary | ||
Switching inputs: | Depending on sensor connected | ||
Switching outputs: | Depending on sensor connected | ||
Оптический индикатор: | 5 LED | ||
Remark (PROFIBUS DP): | Corresponding CMF fieldbus gateway additionally necessary | ||
Конфигурация программного обеспечения: | SOPAS ET |
Механика/электроника | |||
Потребляемая мощность: | Power consumption of the sensor + 1 W | ||
Housing: | Polycarbonat | ||
Enclosure rating: | IP 65 (DIN 40 050) 1) | ||
Класс защиты: | III (VDE 0106) | ||
Вес: | 800 g | ||
Dimensions: | 192 mm x 167 mm x 70 mm | ||
Цвет корпуса: | Blue (RAL 5012) | ||
Подключения сканера: | 15-pin D-Sub HD socket | ||
Сервисный разъем: | 9-pin D-Sub plug (internal) |
Данные окуражающей среды | |||
Ambient operating temperature: | -35 °C ... +40 °C | ||
Storage temperature: | -35 °C ... +70 °C | ||
Permissible relative humidity: | ± 90 %, non-condensing |
At a glance
Efficient solution to power and connect to SICK’s Auto-ID component portfolio |
Slots for optional fieldbus modules, parameter memory, display and power supply module |
Simple voltage supply of scanner |
IP 65 connection of a scanner using SICK standard cable |
Direct access to the service interface of the sensor |
Connection diagram integrated in lid |
Clearly visible and easily accessible screw/spring-loaded terminals |
Your benefits
Easy connection of the sensor to fieldbus systems |
Fast exchange of the sensor through parameter memory CMC |
Fast installation and easy networking save time |
Simple troubleshooting |
Easy diagnosis via optional CMD400 display module |
Features | |||
Краткое описание: | Modular connection module for two sensors | ||
Поддерживаемые продукты: | CLV42x, CLV43x, CLV44x, CLV45x, CLV62x, CLV63x, CLV64x, CLV65x, ICR84x-2, ICR85x-2, IDM12x, IDM14x, IDM16x, IDM24x, IDM26x, Lector®62x, RFH620 | ||
Supports cloning module (CMC): | Yes | ||
Supports display module (CMD): | Yes | ||
Supports power supply module (CMP): | Yes | ||
Supports fieldbus gateway (CMF): | Yes (PROFIBUS DP, Ethernet, DeviceNet) |
Interfaces | |||
Serial (RS-232, RS-422/485): | |||
Remark (Serial (RS-232, RS-422/485)): | Depending on sensor connected | ||
Ethernet: | |||
Remark (Ethernet): | Depending on Sensor connected; corresponding CMF fieldbus gateway additionally necessary | ||
CAN bus: | |||
Remark (CAN bus): | Depending on sensor connected | ||
PROFIBUS DP: | |||
DeviceNet: | |||
Remark (DeviceNet): | Corresponding CMF fieldbus gateway additionally necessary | ||
Switching inputs: | Depending on sensor connected | ||
Switching outputs: | Depending on sensor connected | ||
Оптический индикатор: | 5 LED | ||
Remark (PROFIBUS DP): | Corresponding CMF fieldbus gateway additionally necessary | ||
Конфигурация программного обеспечения: | SOPAS ET |
Механика/электроника | |||
Потребляемая мощность: | Power consumption of the sensor + 1 W | ||
Housing: | Polycarbonat | ||
Enclosure rating: | IP 65 (DIN 40 050) 1) | ||
Класс защиты: | III (VDE 0106) | ||
Вес: | 800 g | ||
Dimensions: | 192 mm x 167 mm x 70 mm | ||
Цвет корпуса: | Blue (RAL 5012) | ||
Подключения сканера: | 15-pin D-Sub HD socket | ||
Сервисный разъем: | 9-pin D-Sub plug (internal) |
Данные окуражающей среды | |||
Ambient operating temperature: | -35 °C ... +40 °C | ||
Storage temperature: | -35 °C ... +70 °C | ||
Permissible relative humidity: | ± 90 %, non-condensing |
At a glance
Efficient solution to power and connect to SICK’s Auto-ID component portfolio |
Slots for optional fieldbus modules, parameter memory, display and power supply module |
Simple voltage supply of scanner |
IP 65 connection of a scanner using SICK standard cable |
Direct access to the service interface of the sensor |
Connection diagram integrated in lid |
Clearly visible and easily accessible screw/spring-loaded terminals |
Your benefits
Easy connection of the sensor to fieldbus systems |
Fast exchange of the sensor through parameter memory CMC |
Fast installation and easy networking save time |
Simple troubleshooting |
Easy diagnosis via optional CMD400 display module |
Features | |||
Краткое описание: | Modular connection module for one sensor, 2 A fuse | ||
Поддерживаемые продукты: | CLV61x - CLV65x, CLV69x, Lector®62x, Lector®65x, RFH6xx, RFU62x, RFU63x | ||
Supports cloning module (CMC): | Yes | ||
Supports display module (CMD): | Yes | ||
Supports power supply module (CMP): | Yes | ||
Supports fieldbus gateway (CMF): | Yes (PROFIBUS DP, Ethernet, DeviceNet) |
Interfaces | |||
Serial (RS-232, RS-422/485): | |||
Remark (Serial (RS-232, RS-422/485)): | Depending on sensor connected | ||
Ethernet: | |||
Remark (Ethernet): | Depending on Sensor connected; corresponding CMF fieldbus gateway additionally necessary | ||
CAN bus: | |||
Remark (CAN bus): | Depending on sensor connected | ||
PROFIBUS DP: | |||
DeviceNet: | |||
Remark (DeviceNet): | Corresponding CMF fieldbus gateway additionally necessary | ||
Switching inputs: | Depending on sensor connected | ||
Switching outputs: | Depending on sensor connected | ||
Оптический индикатор: | 5 LED | ||
Remark (PROFIBUS DP): | Corresponding CMF fieldbus gateway additionally necessary | ||
Конфигурация программного обеспечения: | SOPAS ET |
Механика/электроника | |||
Потребляемая мощность: | Power consumption of the sensor + 1 W | ||
Housing: | Polycarbonat | ||
Enclosure rating: | IP 65 (DIN 40 050) 1) | ||
Класс защиты: | III (VDE 0106) | ||
Вес: | 800 g | ||
Dimensions: | 192 mm x 167 mm x 70 mm | ||
Цвет корпуса: | Blue (RAL 5012) | ||
Подключения сканера: | 15-pin D-Sub HD socket | ||
Сервисный разъем: | 9-pin D-Sub plug (internal) |
Данные окуражающей среды | |||
Ambient operating temperature: | -35 °C ... +40 °C | ||
Storage temperature: | -35 °C ... +70 °C | ||
Permissible relative humidity: | ± 90 %, non-condensing |
At a glance
Efficient solution to power and connect to SICK’s Auto-ID component portfolio |
Slots for optional fieldbus modules, parameter memory, display and power supply module |
Simple voltage supply of scanner |
IP 65 connection of a scanner using SICK standard cable |
Direct access to the service interface of the sensor |
Connection diagram integrated in lid |
Clearly visible and easily accessible screw/spring-loaded terminals |
Your benefits
Easy connection of the sensor to fieldbus systems |
Fast exchange of the sensor through parameter memory CMC |
Fast installation and easy networking save time |
Simple troubleshooting |
Easy diagnosis via optional CMD400 display module |
Features | |||
Краткое описание: | Modular connection module for two sensors, 2 A fuse | ||
Поддерживаемые продукты: | CLV61x - CLV65x, CLV69x, Lector®62x, Lector®65x, RFH6xx, RFU62x, RFU63x | ||
Supports cloning module (CMC): | Yes | ||
Supports display module (CMD): | Yes | ||
Supports power supply module (CMP): | Yes | ||
Supports fieldbus gateway (CMF): | Yes (PROFIBUS DP, Ethernet, DeviceNet) |
Interfaces | |||
Serial (RS-232, RS-422/485): | |||
Remark (Serial (RS-232, RS-422/485)): | Depending on sensor connected | ||
Ethernet: | |||
Remark (Ethernet): | Depending on Sensor connected; corresponding CMF fieldbus gateway additionally necessary | ||
CAN bus: | |||
Remark (CAN bus): | Depending on sensor connected | ||
PROFIBUS DP: | |||
DeviceNet: | |||
Remark (DeviceNet): | Corresponding CMF fieldbus gateway additionally necessary | ||
Switching inputs: | Depending on sensor connected | ||
Switching outputs: | Depending on sensor connected | ||
Оптический индикатор: | 5 LED | ||
Remark (PROFIBUS DP): | Corresponding CMF fieldbus gateway additionally necessary | ||
Конфигурация программного обеспечения: | SOPAS ET |
Механика/электроника | |||
Потребляемая мощность: | Power consumption of the sensor + 1 W | ||
Housing: | Polycarbonat | ||
Enclosure rating: | IP 65 (DIN 40 050) 1) | ||
Класс защиты: | III (VDE 0106) | ||
Вес: | 800 g | ||
Dimensions: | 192 mm x 167 mm x 70 mm | ||
Цвет корпуса: | Blue (RAL 5012) | ||
Подключения сканера: | 15-pin D-Sub HD socket | ||
Сервисный разъем: | 9-pin D-Sub plug (internal) |
Данные окуражающей среды | |||
Ambient operating temperature: | -35 °C ... +40 °C | ||
Storage temperature: | -35 °C ... +70 °C | ||
Permissible relative humidity: | ± 90 %, non-condensing |
At a glance
Efficient solution to power and connect to SICK’s Auto-ID component portfolio |
Slots for optional fieldbus modules, parameter memory, display and power supply module |
Simple voltage supply of scanner |
IP 65 connection of a scanner using SICK standard cable |
Direct access to the service interface of the sensor |
Connection diagram integrated in lid |
Clearly visible and easily accessible screw/spring-loaded terminals |
Your benefits
Easy connection of the sensor to fieldbus systems |
Fast exchange of the sensor through parameter memory CMC |
Fast installation and easy networking save time |
Simple troubleshooting |
Easy diagnosis via optional CMD400 display module |
Features | |||
Краткое описание: | Modular connection module for one sensor, Host and AUX interface available on face plate | ||
Поддерживаемые продукты: | CLV42x, CLV43x, CLV44x, CLV45x, CLV62x, CLV63x, CLV64x, CLV65x, ICR84x-2, ICR85x-2, Lector®62x | ||
Supports cloning module (CMC): | Yes | ||
Supports display module (CMD): | Yes | ||
Supports power supply module (CMP): | Yes | ||
Supports fieldbus gateway (CMF): | No |
Interfaces | |||
Serial (RS-232, RS-422/485): | |||
Remark (Serial (RS-232, RS-422/485)): | Depending on sensor connected | ||
Ethernet: | - | ||
CAN bus: | |||
Remark (CAN bus): | Depending on sensor connected | ||
PROFIBUS DP: | - | ||
DeviceNet: | - | ||
Switching inputs: | Depending on sensor connected | ||
Switching outputs: | Depending on sensor connected | ||
Оптический индикатор: | 5 LED | ||
Конфигурация программного обеспечения: | SOPAS ET |
Механика/электроника | |||
Потребляемая мощность: | Power consumption of the sensor + 1 W | ||
Housing: | Polycarbonat | ||
Enclosure rating: | IP 65 (DIN 40 050) 1) | ||
Класс защиты: | III (VDE 0106) | ||
Вес: | 800 g | ||
Dimensions: | 192 mm x 167 mm x 70 mm | ||
Цвет корпуса: | Blue (RAL 5012) | ||
Подключения сканера: | 15-pin D-Sub HD socket | ||
Сервисный разъем: | 9-pin D-Sub plug (internal) |
Данные окуражающей среды | |||
Ambient operating temperature: | -35 °C ... +40 °C | ||
Storage temperature: | -35 °C ... +70 °C | ||
Permissible relative humidity: | ± 90 %, non-condensing |
At a glance
Efficient solution to power and connect to SICK’s Auto-ID component portfolio |
Slots for optional fieldbus modules, parameter memory, display and power supply module |
Simple voltage supply of scanner |
IP 65 connection of a scanner using SICK standard cable |
Direct access to the service interface of the sensor |
Connection diagram integrated in lid |
Clearly visible and easily accessible screw/spring-loaded terminals |
Your benefits
Easy connection of the sensor to fieldbus systems |
Fast exchange of the sensor through parameter memory CMC |
Fast installation and easy networking save time |
Simple troubleshooting |
Easy diagnosis via optional CMD400 display module |
Features | |||
Краткое описание: | Kit: modular connection module for one sensor, Host and AUX interface available on face plate, power supply CMP400, US power cord | ||
Поддерживаемые продукты: | CLV42x, CLV43x, CLV44x, CLV45x, CLV62x, CLV63x, CLV64x, CLV65x, ICR845-2, ICR84x-2, ICR84x-2 FlexLens, ICR85x-2, Lector®62x, RFH620 | ||
Supports cloning module (CMC): | Yes | ||
Supports display module (CMD): | Yes | ||
Supports power supply module (CMP): | Yes | ||
Supports fieldbus gateway (CMF): | No |
Interfaces | |||
Serial (RS-232, RS-422/485): | |||
Remark (Serial (RS-232, RS-422/485)): | Depending on sensor connected | ||
Ethernet: | - | ||
CAN bus: | |||
Remark (CAN bus): | Depending on sensor connected | ||
PROFIBUS DP: | - | ||
DeviceNet: | - | ||
Switching inputs: | Depending on sensor connected | ||
Switching outputs: | Depending on sensor connected | ||
Оптический индикатор: | 5 LED | ||
Конфигурация программного обеспечения: | SOPAS ET |
Механика/электроника | |||
Потребляемая мощность: | Power consumption of the sensor + 1 W | ||
Housing: | Polycarbonat | ||
Enclosure rating: | IP 65 (DIN 40 050) 1) | ||
Класс защиты: | III (VDE 0106) | ||
Вес: | 800 g | ||
Dimensions: | 192 mm x 167 mm x 70 mm | ||
Цвет корпуса: | Blue (RAL 5012) | ||
Подключения сканера: | 15-pin D-Sub HD socket | ||
Сервисный разъем: | 9-pin D-Sub plug (internal) |
Данные окуражающей среды | |||
Ambient operating temperature: | 0 °C ... +40 °C | ||
Storage temperature: | -20 °C ... +70 °C | ||
Permissible relative humidity: | ± 90 %, non-condensing |
At a glance
Efficient solution to power and connect to SICK’s Auto-ID component portfolio |
Slots for optional fieldbus modules, parameter memory, display and power supply module |
Simple voltage supply of scanner |
IP 65 connection of a scanner using SICK standard cable |
Direct access to the service interface of the sensor |
Connection diagram integrated in lid |
Clearly visible and easily accessible screw/spring-loaded terminals |
Your benefits
Easy connection of the sensor to fieldbus systems |
Fast exchange of the sensor through parameter memory CMC |
Fast installation and easy networking save time |
Simple troubleshooting |
Easy diagnosis via optional CMD400 display module |
Features | |||
Краткое описание: | Modular connection module for one sensor with pre-mounted CMF400 PROFIBUS module (Interface 9-pin D-sub) and integrated CMC parameter cloning module | ||
Поддерживаемые продукты: | CLV42x, CLV43x, CLV44x, CLV45x, CLV62x, CLV63x, CLV64x, CLV65x, ICR84x-2, ICR85x-2 | ||
Supports cloning module (CMC): | Yes | ||
Supports display module (CMD): | Yes | ||
Supports power supply module (CMP): | Yes | ||
Supports fieldbus gateway (CMF): | Integrated (PROFIBUS DP) |
Interfaces | |||
Serial (RS-232, RS-422/485): | |||
Remark (Serial (RS-232, RS-422/485)): | Depending on sensor connected | ||
Ethernet: | |||
Remark (Ethernet): | Corresponding CMF fieldbus gateway additionally necessary | ||
CAN bus: | |||
Remark (CAN bus): | Depending on sensor connected | ||
PROFIBUS DP: | |||
DeviceNet: | |||
Remark (DeviceNet): | Corresponding CMF fieldbus gateway additionally necessary | ||
Switching inputs: | Depending on sensor connected | ||
Switching outputs: | Depending on sensor connected | ||
Оптический индикатор: | 5 LED | ||
Remark (PROFIBUS DP): | CMF400 PROFIBUS-Gateway already integrated | ||
Конфигурация программного обеспечения: | SOPAS ET |
Механика/электроника | |||
Потребляемая мощность: | Power consumption of the sensor + 1 W | ||
Housing: | Polycarbonat | ||
Enclosure rating: | IP 65 (DIN 40 050) 1) | ||
Класс защиты: | III (VDE 0106) | ||
Вес: | 800 g | ||
Dimensions: | 192 mm x 167 mm x 70 mm | ||
Цвет корпуса: | Blue (RAL 5012) | ||
Подключения сканера: | 15-pin D-Sub HD socket | ||
Сервисный разъем: | 9-pin D-Sub plug (internal) |
Данные окуражающей среды | |||
Ambient operating temperature: | 0 °C ... +40 °C | ||
Storage temperature: | -20 °C ... +70 °C | ||
Permissible relative humidity: | ± 90 %, non-condensing |
At a glance
Efficient solution to power and connect to SICK’s Auto-ID component portfolio |
Slots for optional fieldbus modules, parameter memory, display and power supply module |
Simple voltage supply of scanner |
IP 65 connection of a scanner using SICK standard cable |
Direct access to the service interface of the sensor |
Connection diagram integrated in lid |
Clearly visible and easily accessible screw/spring-loaded terminals |
Your benefits
Easy connection of the sensor to fieldbus systems |
Fast exchange of the sensor through parameter memory CMC |
Fast installation and easy networking save time |
Simple troubleshooting |
Easy diagnosis via optional CMD400 display module |
Features | |||
Краткое описание: | Kit: modular connection module for one sensor, 2 A fuse,Host and AUX interface available on face plate, power supply CMP490, US power cord | ||
Поддерживаемые продукты: | CLV69x, Lector®65x, RFU63x | ||
Supports cloning module (CMC): | Yes (depending on sensor connected) | ||
Supports display module (CMD): | No | ||
Supports power supply module (CMP): | Yes (on board) | ||
Supports fieldbus gateway (CMF): | No |
Interfaces | |||
Serial (RS-232, RS-422/485): | |||
Remark (Serial (RS-232, RS-422/485)): | Depending on sensor connected | ||
Ethernet: | - | ||
CAN bus: | |||
Remark (CAN bus): | Depending on sensor connected | ||
PROFIBUS DP: | - | ||
DeviceNet: | - | ||
Switching inputs: | Depending on sensor connected | ||
Switching outputs: | Depending on sensor connected | ||
Оптический индикатор: | 5 LED | ||
Конфигурация программного обеспечения: | SOPAS ET |
Механика/электроника | |||
Потребляемая мощность: | Power consumption of the sensor + 1 W | ||
Housing: | Polycarbonat | ||
Enclosure rating: | IP 20 (DIN 40 050) 1) | ||
Класс защиты: | III (VDE 0106) | ||
Вес: | 1,427.8 g | ||
Dimensions: | 192 mm x 167 mm x 70 mm | ||
Цвет корпуса: | Blue (RAL 5012) | ||
Подключения сканера: | 15-pin D-Sub HD socket | ||
Сервисный разъем: | 9-pin D-Sub plug (internal) |
Данные окуражающей среды | |||
Electromagnetic compatibility (EMC): | EN 61000-6-4 (2007-01) / EN 61000-6-2 (2005-08) | ||
Ambient operating temperature: | -35 °C ... +40 °C | ||
Storage temperature: | -20 °C ... +70 °C | ||
Permissible relative humidity: | ± 90 %, non-condensing | ||
Electrical safety: | EN 61010 (2010-01) |
At a glance
Efficient solution to power and connect to SICK’s Auto-ID component portfolio |
Slots for optional fieldbus modules, parameter memory, display and power supply module |
Simple voltage supply of scanner |
IP 65 connection of a scanner using SICK standard cable |
Direct access to the service interface of the sensor |
Connection diagram integrated in lid |
Clearly visible and easily accessible screw/spring-loaded terminals |
Your benefits
Easy connection of the sensor to fieldbus systems |
Fast exchange of the sensor through parameter memory CMC |
Fast installation and easy networking save time |
Simple troubleshooting |
Easy diagnosis via optional CMD400 display module |
Features | |||
Краткое описание: | Modular connection module for one sensor with pre-mounted CMF400 PROFIBUS module (Interface 2 x M12) and integrated CMC parameter cloning module | ||
Поддерживаемые продукты: | CLV42x, CLV43x, CLV44x, CLV45x, CLV62x, CLV63x, CLV64x, CLV65x, ICR84x-2, ICR85x-2 | ||
Supports cloning module (CMC): | Yes | ||
Supports display module (CMD): | Yes | ||
Supports power supply module (CMP): | Yes | ||
Supports fieldbus gateway (CMF): | Integrated (PROFIBUS DP) |
Interfaces | |||
Serial (RS-232, RS-422/485): | |||
Remark (Serial (RS-232, RS-422/485)): | Depending on sensor connected | ||
Ethernet: | |||
Remark (Ethernet): | Corresponding CMF fieldbus gateway additionally necessary | ||
CAN bus: | |||
Remark (CAN bus): | Depending on sensor connected | ||
PROFIBUS DP: | |||
DeviceNet: | |||
Remark (DeviceNet): | Corresponding CMF fieldbus gateway additionally necessary | ||
Switching inputs: | Depending on sensor connected | ||
Switching outputs: | Depending on sensor connected | ||
Оптический индикатор: | 5 LED | ||
Remark (PROFIBUS DP): | CMF400 PROFIBUS-Gateway already integrated | ||
Конфигурация программного обеспечения: | SOPAS ET |
Механика/электроника | |||
Потребляемая мощность: | Power consumption of the sensor + 1 W | ||
Housing: | Polycarbonat | ||
Enclosure rating: | IP 65 (DIN 40 050) 1) | ||
Класс защиты: | III (VDE 0106) | ||
Вес: | 800 g | ||
Dimensions: | 192 mm x 167 mm x 70 mm | ||
Цвет корпуса: | Blue (RAL 5012) | ||
Подключения сканера: | 15-pin D-Sub HD socket | ||
Сервисный разъем: | 9-pin D-Sub plug (internal) |
Данные окуражающей среды | |||
Ambient operating temperature: | 0 °C ... +40 °C | ||
Storage temperature: | -20 °C ... +70 °C | ||
Permissible relative humidity: | ± 90 %, non-condensing |