* When ordering for the first time, please use the information in "Model Name" instead of "Part No."

At a glance

  • Large display
  • Individually programmable transistor outputs PNP or NPN, optional analog output 4 mA ... 20 mA or 0 V ... 10 V
  • Round connector M12 x 1
  • Measuring ranges -20 °C ... +80 °C
  • Pt1000 element, accuracy class A (IEC 60751)
  • Various insertion lengths and connection threads
  • Wetted parts made from corrosion-resistant stainless steel 1.4571
  • Enclosure rating IP 65 and IP 67

    Your benefits

  • Quick and safe set-up through superior ease of use
  • Compact dimensions and rotatable housing facilitate integration
  • Very reliable: splash-proof housing, high-grade materials, rugged design, and field-proven technology
  • Very good long-term stability, accuracy and linearity
  • Quick response time
  • Versatile configuration allows for optimal solutions for specific requirements
    Арт. -*
    Features
    Measuring range: -20 °C ... 80 °C
    Чувствительный элемент: Pt1000, 2-wire, class A according to IEC 60751
    Output signals: 2 x NPN
    1 x 0 V ... 10 V
    Output type: Transistor
    Switching output function: Normally open/normally closed, windows- and hysteresis function freely adjustable
    Switching voltage: Supply voltage [V DC] - 1 V DC
    Максимальный коммутируемый ток: 250 mA
    Switching delay: 0 s ... 50 s, programmable
    Setting accuracy of switching outputs: 0.1 °C
    Temperature offset: ± 3 °C
    Messbereichskalierung: Zero point: max. +25 % of span
    Full scale: max. -25 % of span
    Display: 14-segment LED, blue, 4-digits, height 9 mm, display electronically turnable by 180 °, update: 200 ms
    Rotatable housing: Display against housing with electrical connection: 330 °, Housing against process connection: 320 °
    Performance
    Accuracy of sensor element: ≤ ± (0.15 °C + 0.002 |t|) 1)
    Accuracy of switching output: ≤ ± 0.8 % of span
    Display accuracy: ≤ ± 0.8 % of span ± 1 digit
    Accuracy of analog output: ≤ ± 0,5 % of span
    Response time t50: ≤ 5 s 2)
    Response time t90: ≤ 10 s 3)
    Механика/электроника
    Process connection: Thread 1/4'' NPT
    Insertion length/diameter of probe: 250 mm / 6 mm
    Материал корпуса: Lower body: stainless steel 1.4301 (AISI 304)
    Plastic head: PC + ABS
    Input keypad: TPE-E
    Display window: PC
    Детали, контактирующие с измеряемой средой: Stainless steel 1.4571 (AISI 316Ti)
    Supply voltage: 15 V DC ... 35 V DC
    CE-conformity: 2004/108/EC, EN 61326-1 emission (group 1, class B) and interference immunity (industrial application)
    Maximum power consumption: 70 mA
    Seal: Without seal
    Maximum process pressure: 150 bar 1)
    Enclosure rating: IP 65, according to IEC 60529
    IP 67, according to IEC 60529 2)3)
    Тип подключения: Round connector M12 x 1, 5-pin
    Maximum ohmic load RA: ≤ 100 kΩ (Switching outputs)
    > 10 kΩ (output signal 0 V ... 10 V)
    Total current consumption: 570 mA (incl. switching current)
    320 mA
    Класс защиты: III
    Isolation voltage: 500 V DC
    Overvoltage protection: 40 V DC
    защита от короткого замыкания: Outputs QA, Q1, Q2 towards M
    Защита от обратной полярности: L+ towards M
    RoHS certificate:
    Данные окуражающей среды
    Ambient temperature: -20 °C ... 80 °C
    Storage and transport temperature: -20 °C ... 80 °C
    Relative humidity: 45 % ... 75 %
     