At a glance
Rugged device design |
Several housing materials and electrical outputs available |
Immune to deposit formation |
Commissioning without filling |
Process temperature up to 250 °C |
Very high repeatability |
ATEX versions (1D/2D/1G/2G) available |
Tube extensions (LBV330) and rope extensions (LBV320) available for vertical mounting up to 80 m distance |
Your benefits
Easy installation and commissioning, no calibration necessary |
Easy operation and integration, saves time |
Maintenance-free sensor, reduces downtime |
Testing in place possible - no mounting required, which reduces installation time |
Flexible and tough system for a multitude of applications |
Features | |||
Средний: | Bulk solids | ||
Measurement: | Switch | ||
Длина зонда: | 220 mm | ||
Давление процесса: | -1 bar ... 25 bar | ||
Температура процесса: | -50 °C ... 150 °C | ||
ATEX approval: | ATEX II 1D, 1/2D, 2D Ex t IIIC T... Da, Da/Db, Db IP66 | ||
Particle size: | |||
Fill material density: | ≥ 0.008 | ||
Type examination: | TÜV 09 ATEX 555503 |
Performance | |||
Accuracy of sensor element: | ± 10 mm | ||
Повторяемость: | ≤ 5 mm | ||
Response time: | 500 ms when covered / 1000 ms when uncovered |
Mechanical data | |||
Материал корпуса: | Aluminum | ||
Process connection: | G 1½ A PN 25 | ||
Sensor material: | Stainless steel 1.4404 |
Electrical data | |||
Enclosure rating: | IP 66 / IP 67 | ||
Supply voltage: | Transistor output PNP/ NPN: 10 V DC ... 55 V DC | ||
Пульсации: | ≤ 5 Vpp | ||
Потребляемая мощность: | |||
VDE protection class 2: | ![]() |
||
Время инициализации: | |||
Hysteresis: | 10 mm | ||
Output current: | |||
Сигнал Высокого напряжения: | Uv - 3 V | ||
Signal voltage LOW: | |||
Capacitive load: | 100 nF | ||
Inductive load: | ≤ 1 H | ||
Тип подключения: | M20 x 1.5 |
Данные окуражающей среды | |||
Ambient operating temperature: | -40 °C ... 80 °C | ||
Температура хранения: | -40 °C ... 80 °C |
At a glance
Rugged device design |
Several housing materials and electrical outputs available |
Immune to deposit formation |
Commissioning without filling |
Process temperature up to 250 °C |
Very high repeatability |
ATEX versions (1D/2D/1G/2G) available |
Tube extensions (LBV330) and rope extensions (LBV320) available for vertical mounting up to 80 m distance |
Your benefits
Easy installation and commissioning, no calibration necessary |
Easy operation and integration, saves time |
Maintenance-free sensor, reduces downtime |
Testing in place possible - no mounting required, which reduces installation time |
Flexible and tough system for a multitude of applications |
Features | |||
Средний: | Bulk solids | ||
Measurement: | Switch | ||
Длина зонда: | 200 mm | ||
Давление процесса: | -1 bar ... 25 bar | ||
Температура процесса: | -50 °C ... 150 °C | ||
ATEX approval: | ATEX II 1D, 1/2D, 2D Ex t IIIC T... Da, Da/Db, Db IP66 | ||
Particle size: | |||
Fill material density: | ≥ 0.008 | ||
Type examination: | TÜV 09 ATEX 555503 |
Performance | |||
Accuracy of sensor element: | ± 10 mm | ||
Повторяемость: | ≤ 5 mm | ||
Response time: | 500 ms when covered / 1000 ms when uncovered |
Mechanical data | |||
Материал корпуса: | Stainless steel (casted) 316L | ||
Process connection: | 1 1/2" NPT PN 25 / stainless steel 316L | ||
Sensor material: | Stainless steel 1.4404 |
Electrical data | |||
Enclosure rating: | IP 66 / IP 67 | ||
Supply voltage: | NAMUR signal: 4.5 V DC ... 12 V DC | ||
Потребляемая мощность: | 1 mA / 2,5 mA | ||
VDE protection class 2: | ![]() |
||
Время инициализации: | |||
Hysteresis: | 10 mm | ||
Output current: | 1 mA / 2,5 mA | ||
Тип подключения: | ½" NPT |
Данные окуражающей среды | |||
Ambient operating temperature: | -40 °C ... 80 °C | ||
Температура хранения: | -40 °C ... 80 °C |
At a glance
Rugged device design |
Several housing materials and electrical outputs available |
Immune to deposit formation |
Commissioning without filling |
Process temperature up to 250 °C |
Very high repeatability |
ATEX versions (1D/2D/1G/2G) available |
Tube extensions (LBV330) and rope extensions (LBV320) available for vertical mounting up to 80 m distance |
Your benefits
Easy installation and commissioning, no calibration necessary |
Easy operation and integration, saves time |
Maintenance-free sensor, reduces downtime |
Testing in place possible - no mounting required, which reduces installation time |
Flexible and tough system for a multitude of applications |
Features | |||
Средний: | Bulk solids | ||
Measurement: | Switch | ||
Длина зонда: | 220 mm | ||
Давление процесса: | -1 bar ... 25 bar | ||
Температура процесса: | -50 °C ... 150 °C | ||
ATEX approval: | ATEX II 1/2G, II 2G Ex d IIC T1... T6 Ga/Gb, Gb | ||
Particle size: | |||
Fill material density: | ≥ 0.008 | ||
Type examination: | TÜV 12 ATEX 110288 X |
Performance | |||
Accuracy of sensor element: | ± 10 mm | ||
Повторяемость: | ≤ 5 mm | ||
Response time: | 500 ms when covered / 1000 ms when uncovered |
Mechanical data | |||
Материал корпуса: | Plastic | ||
Process connection: | G 1½ A PN 25 | ||
Sensor material: | Stainless steel 1.4404 |
Electrical data | |||
Enclosure rating: | IP 66 / IP 67 | ||
Supply voltage: | Double relay (DPDT): 20 V DC ... 72 V DC / 20 ... 253 V AC | ||
Потребляемая мощность: | 5 mA ... 30 mA | ||
VDE protection class 1: | ![]() |
||
Время инициализации: | |||
Hysteresis: | 10 mm | ||
Output current: | > 10 µA; | ||
Capacitive load: | 100 nF, 750 VA 54 W | ||
Inductive load: | ≤ 1 H, 750 VA 54 W | ||
Тип подключения: | M20 x 1.5 |
Данные окуражающей среды | |||
Ambient operating temperature: | -40 °C ... 80 °C | ||