Technical data |
|
Moment of inertia of the rotor: |
54 gcm² |
|
|
Шаг измерения: |
360°/number of steps |
|
|
Repeat accuracy: |
0.005° |
|
|
Error limits binary number of steps: |
0.035 ° |
|
|
Error limits non-binary number of steps: |
0.046 ° |
|
|
Measured value backlash: |
0.005 ° |
|
|
Response threshold: |
0.003 ° |
|
|
Ambient operation temperature, min ... max:: |
-20 °C ... +85 °C |
|
|
Max. operating speed with shaft seal: |
6,000 U/min |
|
|
Max. operating speed without shaft seal: |
10,000 U/min |
|
|
Момент вращения: |
2.6 Ncm |
|
|
Крутящий момент на старте: |
3.4 Ncm |
|
|
Permissible shaft loading axial: |
10 N |
|
|
Permissible shaft loading radial: |
20 N |
|
|
Устойчивость к ударам: |
50/11 g/ms |
|
|
Resistance to vibration: |
20/10 ... 150 g/Hz |
|
|
Enclosure rating:: |
IP 66 |
|
|
Supply current: |
90 mA |
|
|
Установка нуля: |
≥ 100 ms |
|
|
Initialisation time after power on: |
40 |
|
|
Permissible relative humidity: |
90 % |
|
|
Covered reading field: |
0.003 ° |
|
|
Working temperature range read head: |
-20 °C ... +85 °C |
|
|
Storage temperature range read head: |
-40 °C 100 °C |
|
|
Supply voltage:: |
90 mA |
|