At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | SSI | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | PROFIBUS DP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | RS-422 | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | CANopen | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | EtherNet/IP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | PROFINET | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | SSI | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | PROFIBUS DP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | RS-422 | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | CANopen | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | EtherNet/IP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 60 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 3 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | PROFINET | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | SSI | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | PROFIBUS DP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | RS-422 | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | CANopen | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | EtherNet/IP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | PROFINET | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | SSI | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | PROFIBUS DP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | RS-422 | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | CANopen | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | EtherNet/IP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 130 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 4 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | PROFINET | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | SSI | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | PROFIBUS DP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | RS-422 | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | CANopen | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | EtherNet/IP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 0 |
Interfaces | |||
Интерфейс передачи данных: | PROFINET | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation: -20 ... +55 °C Operation with cooling case: -20 ... +75 °C Storage: -40 ... +75 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | SSI | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | PROFIBUS DP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | RS-422 | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | CANopen | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | EtherNet/IP | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |
At a glance
Measuring range up to 220 m (dependent on type) |
Numerous fieldbus interfaces |
Pre-failure notification and diagnostic data available |
Display with intuitive menu structure and clearly visible status LEDs |
Small, rugged metal housing |
3-axis alignment bracket with quick-lock system as accessory available |
Elongated holes for zero point adjustment when replacing devices |
Your benefits
100,000 hours of laser service life ensures that the sensor will have a long, useful life with maximum reliability |
Versions with integrated heating enable reliable use at ambient temperatures at up to -40°C. The TPCC cooling housing, available as an option, enables use at up to +75°C |
The numerous interfaces offer a high degree of flexibility as well as rapid communication for maximum productivity |
Pre-failure notification and diagnostic data for maximum plant availability |
Small, rugged metal housing with SpeedConâ„¢ compatible connectors ensures smooth handling - even in confined spaces |
Alignment bracket with quick lock system ensures fast alignment and easy device replacement, reducing maintenance and mounting costs |
Performance | |||
Measuring range: | 0.15 m ... 220 m, On reflective tape "Diamond Grade" | ||
Resolution: | 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm | ||
Repeatability 1): | 2.5 mm (at dead time 10 ms), 1.25 mm (at dead time 30 ms) | ||
Accuracy 2): | ± 5 mm | ||
Light source 3): | Laser, red | ||
Typ. light spot size (distance): | 5 mm (+ 2 mm x distance in m) | ||
Internal measurement cycle: | 1 ms | ||
Макс. скорость передвижения: | 30 m/s | ||
Laser class: | 2 (EN 60825-1 / CDRH) | ||
Output time: | Synchronous to PLC request (dependent on interfaces) | ||
Heating: | 1 |
Interfaces | |||
Интерфейс передачи данных: | PROFINET | ||
Output type 1): | B (push/pull) MF1, MF2 |
||
Multifunctional input (MF) 2): | 1 x MF1 |
Механика/электроника | |||
Supply voltage Vs: | DC 18 V ... 30 V, limit values | ||
Ripple 1): | 5 Vpp | ||
Initialization time 2): | Typ. 1.5 s | ||
Индикатор: | 6 digit 5 x 7 dot matrix display, LEDs | ||
Weight 3): | Ca. 800 g ... 1,600 g | ||
Output current IA 4): | ≤ 100 mA | ||
Потребляемая мощность: | At 24 V DC | ||
Тип подключения: | Male connector, M12, SPEEDCONâ„¢ compatible | ||
Материал корпуса: | Aluminum/zinc die-cast | ||
Modulation frequency: | Fix |
Данные окуражающей среды | |||
Enclosure rating: | IP 65 | ||
Класс защиты: | III | ||
Effect of air pressure: | 0.3 ppm/hPa | ||
Effect of air temperature: | 1 ppm/K | ||
Температурный дрейф: | Typ. 0.1 mm/K | ||
Ambient temperature 1): | Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C |
||
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 |
||
Electromagnetic compatibility (EMC) 2): | EN 61000-6-2 / EN 61000-6-4 |