At a glance
Up to 6 x PNP or NPN switching outputs and two switching inputs |
Resolutions of 10 / 20 / 30 / 50 mm and customer-specific resolutions |
Working range up to 5 m |
Detection heights of over 3 m and up to 150 beams possible |
Short response time |
External teach-in for optimal sensitivity settings |
Highest immunity to sunlight |
Scratch-resistant front lens |
Your benefits
Highest immunity to sunlight for trouble-free operation |
Intelligent evaluation software saves costs |
Easy-to-see status information helps avoid interrupting operation |
Different beam separation options, detection heights and output configurations ensure a reliable solution |
Features | |||
Технологии: | Sender/receiver | ||
Задачи: | Measurement light grid | ||
Minimum detectable object (MDO) 1): | Parallel beam, 35 mm | ||
Расстояние между лучами: | 30 mm | ||
Количество лучей: | 50 | ||
Высота обнаружения: | 1,470 mm | ||
Конфигурации: | Parameterization interface (measuring) |
Performance | |||
Maximum range 1): | 7 m | ||
Минимальный диапазон | Parallel beam: ≥0 mm | ||
Response time 2): | Parallel beam: ≥8.5 ms | ||
Working range 3): | 5 m |
Interfaces | |||
Output type: | 3 x PNP | ||
Inputs: | 1 x PNP | ||
Тип подключения: | Male connector M12, 8-pin |
Механика/электроника | |||
Длина волны: | IR 880 nm | ||
Supply voltage Vs 1): | DC 18 V ... 30 V | ||
Power consumption sender 2): | 240 mA | ||
Power consumption receiver 3): | 250 mA | ||
Пульсации: | |||
Output current Imax.: | 100 mA | ||
Output load capacitive: | 100 nF | ||
Выходная нагрузка индуктивная: | 1 H | ||
Время инициализации: | 1 s | ||
Dimensions (W x H x D): | 34 mm x 1,564 mm x 29 mm | ||
Материал корпуса: | Aluminum | ||
Индикатор: | 7-segment display, LED | ||
Синхронизации: | Cable | ||
Enclosure rating: | IP 65 | ||
Защита цепи: | Output Q short-circuit protected, Interference suppression, VS connections reverse-polarity protected | ||
Вес: | 3.881 kg | ||
Передний экран: | PMMA |
Данные окуражающей среды | |||
Класс защиты: | III | ||
EMC: | EN 60947-5-2 | ||
Ambient temperature: | Operation: -25 ... +55 °C, Storage: -40 ... +70 °C | ||
Ambient light safety 1)2): | Direct: ≥150,000 lx, Indirect: ≥200,000 lx | ||
Виброустойчивость: | 5 g, 10 Hz ... 55 Hz (IEC 68-2-6) | ||
Shock load: | 10 g / IEC 68-2-29 / 16 ms |