High reliability and precision are the distinguishing features of the GME700 laser gas analyzer. Based on the principle of TDLS (Tunable Diode Laser Spectroscopy) and by using specific light absorption, the GME700 is able to measure several gas components, such as NH3, HF, O2 or HCl. The compact 19" unit includes the analyzer and evaluation unit as well as a heated multipath measuring cell.

At a glance

  • High selectivity due to high spectral resolution
  • No calibration required
  • No moving parts: minimal wear and tear
  • Heated multipath measuring cell
  • Hot-wet measurement

    Your benefits

  • Best application match by adapting the gas conditioning
  • High reliability during operation
  • Also applicable for harsh environment conditions
  • Easy integration into existing extractive systems
  • No problematic test gases required

    Fields of application

  • Ammonia slip measurement in DeNOx plants
  • Measurement of hydrogen fluoride in semiconductor production
  • Ammonia measurement in exhaust gas of combustion engines
  • Ammonia measurement in urea production or composting plants
  • Plastics processing
  • Hydrogen chloride monitoring in raw gas before scrubber in waste incineration plants
    Technical data
    Measurement principles: Diode laser spectroscopy (TDLS)
    Measured values: H2O, HCl, HF, NH3, O2
    Max. number of measurands: 2
    Measuring ranges: HCl: 0 ... 5 ppm / 0 ... 3,000 ppm
    HF: 0 ... 5 ppm / 0 ... 2,000 ppm
    NH3: 0 ... 25 ppm / 0 ... 5,000 ppm
    O2: 0 ... 7 Vol.-% / 0 ... 25 Vol.-%
    Comment: Measuring ranges depend on application and device version
    Length of measuring path: 2.3 ... 4.5 m
    Gas flow rate: 0 ... 20 l/min
    depending on application
    Температура процесса: ≤+120 °C
    temperature at analyzer inlet
    Давление процесса: 600 ... 1,200 hPa
    Ambient temperature: 0 ... +50 °C
    Ambient humidity: 0 ... 85 %
    relative humidity; non-condensing
    Electrical safety: CE
    Enclosure rating: IP 20
    Analog outputs: 3 outputs:
    0/4 ... 20 mA, 500 Ω
    Digital outputs: 3 relay contacts:
    48 V AC/DC
    preset for failure, maintenance and functional control
    Digital inputs: 2 potential-free contacts:
    24 V DC
    Interfaces: RS-232 (service interface)
    Bus protocol: PROFIBUS DP (option)
    Operation: Via LC-display and function keys
    Device version: 19''-rack
    System components: Analyzer
    Test functions: Automatic check cycle for zero and span point
     
     

     
     
     