Multi component analyzing system, MCS300P HW

Главная » Продукция » SICK » Анализаторы » Analyzer solutions » Multi component analyzing system, MCS300P HW
 
 

The MCS300P HW is a hot/extractive analyzer system for measurement of gases. It measures IR- or VIS-active components with variable measuring ranges for monitoring and controlling of combustion and flue gas conditioning. The heated system components prevent a temperature drop below the water and acid dewpoint. This results in lower maintenance and higher reliablity and long-time stablity of the system, also under rugged and demanding conditions. Automatic adjustment functions, easy operation concept and modern communication protocols results in a quick and easy integration into a local control system network.

At a glance

  • Simultaneous measurement of up to 6 components plus O2
  • Sample flow control and sample gas pressure measurement
  • Temperature of heated system components up to 220 °C
  • Automatic sample point switching for up to 8 sample points (option)
  • Automatic adjustment of zero and span point
  • Integrated adjustment unit without span gas (option)
  • Extended operation via PC and software
  • Flexible I/O modules

    Your benefits

  • Economic, automatic adjustment without expensive test gases
  • Easy remote control by integration in existing networks
  • Automatic control of the complete measuring system and probe
  • Low maintenance and reliable due to hot measurement
  • In combination with probe SCP3000 also for measurements at high dust loads and high temperatures
  • Short response time due to high sample gas flow

    Fields of application

  • Monitoring of flue gas conditioning in waste or sewage sludge incinerators
  • Monitoring of the scrubber in flue gas conditioning
  • Measurement directly at the kiln inlet in cement plants
    Technical data
    Analyzer: MCS300P
    Measurement principles: Gas filter correlation, Interference filter correlation, Zirconium dioxide sensor
    Measured values: CO, CO2, H2O, HCl, N2O, NH3, NO, NO2, O2, SO2
    Max. number of measurands: 6
    Measuring ranges: CO: 0 ... 800 ppm / 0 ... 5 Vol.-%
    CO2: 0 ... 20 Vol.-% / 0 ... 100 Vol.-%
    H2O: 0 ... 1 Vol.-% / 0 ... 60 Vol.-%
    HCl: 0 ... 700 ppm / 0 ... 12,000 ppm
    N2O: 0 ... 500 ppm / 0 ... 7,500 ppm
    NH3: 0 ... 550 ppm / 0 ... 5,000 ppm
    NO: 0 ... 750 ppm / 0 ... 15,000 ppm
    NO2: 0 ... 500 ppm / 0 ... 4,000 ppm
    O2: 0 ... 1 Vol.-% / 0 ... 21 Vol.-%
    SO2: 0 ... 200 ppm / 0 ... 10 Vol.-%
    Comment: 2 measuring ranges per component, Other measuring ranges and components on request
    Gas flow rate: 150 ... 800 l/h
    Температура процесса: Sample gas inlet: ≤+220 °C
    Process: ≤+1,300 °C
    depending on sampling probe
    Давление процесса: 800 ... 1,200 hPa
    Ambient temperature: +5 ... +35 °C
    temperature change ±10 °C/h maximum
    With cooling device: +5 ... +45 °C
    temperature change ±10 °C/h maximum; other temperatures on request
    Ambient humidity: ≤80 %
    non-condensing
    Electrical safety: CE
    Enclosure rating: IP 43
    versions with NOx-converter (option)
    Analog outputs: 2 outputs:
    0/4 ... 22 mA, 500 Ω
    electrically isolated; additional outputs if using I/O modules (option)
    Analog inputs: 2 inputs:
    0/4 ... 22 mA, 100 Ω
    electrically isolated; additional inputs if using I/O modules (option)
    Digital outputs: 2 power relays
    electrically isolated; additional outputs if using I/O modules (option)
    3 potential-free contacts
    additional outputs if using I/O modules
    Digital inputs: 2 potential-free contacts
    additional inputs if using I/O modules
    Interfaces: Ethernet
    Bus protocol: Modbus TCP
    OPC
    Operation: Application specific programs for system control, Via operating unit in the analyzer, Via software SOPAS ET, Two operating levels, one password-protected
    Device version: Steel sheet cabinet
    System components: Analyzer cabinet
    Sampling probe
    Sample gas line, heated
    Sample point switching (max. 8 sample points)
    Test functions: Automatic check cycle for zero and span point
    Corrective functions: Internal adjustment unit (option)
    Cross-sensitivity compensation of up to 6 interferents
     
     

     
     
     