The FTIR measuring principle allows the simultaneous determination of more than 12 measuring components - tailor-made for the particular requirements of the customer. The MCS100FT FTIR analyzer system with its heated measuring cell enables the monitoring of hydrogen fluoride limits as requested by legislation. The MCS100FT is equipped with an oxygen sensor as standard and can be supplemented with a total hydrocarbon analyzer. With its reliable measuring technology, its easy operation and low maintenance requirements, the MCS100FT provides a solution that offers unequalled opportunities.
At a glance
Lowest approved HF measuring range of 0 ... 3 mg/m3 |
Automatic spectrum adjustment via AutoVAL for reliable measuring values |
Operation via touchscreen |
Sample gas transport by an ejector without moving parts |
Approved according to EN 15267-3 |
Remote control and diagnosis via software SOPAS ET |
Automatic adjustment of analyzer |
Automatic backflushing and filter cleaning of sampling unit |
Your benefits
Proper HF limit value monitoring |
Only one analyzer for more than 12 measuring components |
Easy integration into the customer network environment |
Long maintenance interval of 6 months for many measuring components |
Type approved measurement of greenhouse gases such as N2O, CH4 and CO2 |
Low maintenance requirements |
Fields of application
Emission monitoring in waste incineration plants |
Effective HF limit value monitoring, e.g in aluminum production |
Monitoring of gaseous emission of cement plants or power stations |
Technical data | |||
Analyzer: | MCS100FT | ||
Measurement principles: | Flame ionisation detection, FTIR spectroscopy, Zirconium dioxide sensor | ||
Measured values: | C2H6, C3H8, CH4, CO, CO2, Corg, H2O, HCl, HF, N2O, NH3, NO, NO2, NOx, O2, SO2 | ||
Performance-tested measurands: | C2H6, CH4, CO, CO2, Corg, H2O, HCl, HF, N2O, NH3, NO, NO2, O2, SO2 | ||
Max. number of measurands: | 16 | ||
Measuring ranges: | C2H6: 0 ... 40 ppm C3H8: 0 ... 25 ppm Corg: 0 ... 7.5 ppm / 0 ... 75 ppm CH4: 0 ... 70 ppm / 0 ... 210 ppm CO: 0 ... 60 ppm / 0 ... 1,200 ppm CO2: 0 ... 25 Vol.-% H2O: 0 ... 40 Vol.-% HCl: 0 ... 10 ppm / 0 ... 100 ppm HF: 0 ... 3 ppm / 0 ... 10 ppm N2O: 0 ... 25 ppm / 0 ... 250 ppm NH3: 0 ... 13 ppm / 0 ... 65 ppm NO: 0 ... 150 ppm / 0 ... 1,500 ppm NO2: 0 ... 25 ppm / 0 ... 250 ppm NOx: 0 ... 100 ppm / 0 ... 1,000 ppm O2: 0 ... 21 Vol.-% SO2: 0 ... 25 ppm / 0 ... 525 ppm |
||
Comment: | Other measuring ranges and components on request, Measuring ranges depend on application and device version | ||
Length of measuring path: | ≤8.5 m optical path length of measuring cell |
||
Gas flow rate: | ≤300 l/h | ||
Температура процесса: | ≤+1,300 °C ≤+200 °C temperature at analyzer inlet |
||
Давление процесса: | 900 ... 1,100 hPa | ||
Ambient temperature: | With cooling device: +5 ... +50 °C Standard: +5 ... +35 °C |
||
Ambient pressure: | 900 ... 1,100 bar | ||
Ambient humidity: | 0 ... 80 % relative humidity; non-condensing |
||
Conformities: | 2000/76/EC 2001/80/EC 27. BImSchV EN 14181 EN 15267 |
||
Electrical safety: | CE | ||
Enclosure rating: | IP 43 Optional: IP 54 |
||
Analog outputs: | Outputs: 0/4 ... 22 mA, 500 Ω number depends on system configuration; electrically isolated; max. 32 outputs |
||
Analog inputs: | Inputs: 0/4 ... 22 mA, 100 Ω number depends on system configuration; electrically isolated; max. 32 inputs |
||
Digital outputs: | Outputs: 48 V AC, 0.5 A, 35 VA / 48 V DC, 0.5 A, 24 Wnumber depends on system configuration; electrically isolated; max. 64 outputs |
||
Digital inputs: | Inputs: 3.9 V, 4.5 mA, 0.55 W number depends on system configuration; max. 64 inputs |
||
Interfaces: | Ethernet RS-422/RS-485 |
||
Bus protocol: | Ethernet TCP/IP Modbus OPC |
||
Operation: | Several operating levels, password-protected, Via LC-display or software SOPAS ET | ||
System components: | Analyzer I/O module Control unit Temperature control unit |
||
Test functions: | Internal zero point check | ||
Corrective functions: | Internal adjustment unit (option) |