The FTIR measuring principle allows the simultaneous determination of more than 12 measuring components - tailor-made for the particular requirements of the customer. The MCS100FT FTIR analyzer system with its heated measuring cell enables the monitoring of hydrogen fluoride limits as requested by legislation. The MCS100FT is equipped with an oxygen sensor as standard and can be supplemented with a total hydrocarbon analyzer. With its reliable measuring technology, its easy operation and low maintenance requirements, the MCS100FT provides a solution that offers unequalled opportunities.

At a glance

  • Lowest approved HF measuring range of 0 ... 3 mg/m3
  • Automatic spectrum adjustment via AutoVAL for reliable measuring values
  • Operation via touchscreen
  • Sample gas transport by an ejector without moving parts
  • Approved according to EN 15267-3
  • Remote control and diagnosis via software SOPAS ET
  • Automatic adjustment of analyzer
  • Automatic backflushing and filter cleaning of sampling unit

    Your benefits

  • Proper HF limit value monitoring
  • Only one analyzer for more than 12 measuring components
  • Easy integration into the customer network environment
  • Long maintenance interval of 6 months for many measuring components
  • Type approved measurement of greenhouse gases such as N2O, CH4 and CO2
  • Low maintenance requirements

    Fields of application

  • Emission monitoring in waste incineration plants
  • Effective HF limit value monitoring, e.g in aluminum production
  • Monitoring of gaseous emission of cement plants or power stations
    Technical data
    Analyzer: MCS100FT
    Measurement principles: Flame ionisation detection, FTIR spectroscopy, Zirconium dioxide sensor
    Measured values: C2H6, C3H8, CH4, CO, CO2, Corg, H2O, HCl, HF, N2O, NH3, NO, NO2, NOx, O2, SO2
    Performance-tested measurands: C2H6, CH4, CO, CO2, Corg, H2O, HCl, HF, N2O, NH3, NO, NO2, O2, SO2
    Max. number of measurands: 16
    Measuring ranges: C2H6: 0 ... 40 ppm
    C3H8: 0 ... 25 ppm
    Corg: 0 ... 7.5 ppm / 0 ... 75 ppm
    CH4: 0 ... 70 ppm / 0 ... 210 ppm
    CO: 0 ... 60 ppm / 0 ... 1,200 ppm
    CO2: 0 ... 25 Vol.-%
    H2O: 0 ... 40 Vol.-%
    HCl: 0 ... 10 ppm / 0 ... 100 ppm
    HF: 0 ... 3 ppm / 0 ... 10 ppm
    N2O: 0 ... 25 ppm / 0 ... 250 ppm
    NH3: 0 ... 13 ppm / 0 ... 65 ppm
    NO: 0 ... 150 ppm / 0 ... 1,500 ppm
    NO2: 0 ... 25 ppm / 0 ... 250 ppm
    NOx: 0 ... 100 ppm / 0 ... 1,000 ppm
    O2: 0 ... 21 Vol.-%
    SO2: 0 ... 25 ppm / 0 ... 525 ppm
    Comment: Other measuring ranges and components on request, Measuring ranges depend on application and device version
    Length of measuring path: ≤8.5 m
    optical path length of measuring cell
    Gas flow rate: ≤300 l/h
    Температура процесса: ≤+1,300 °C
    ≤+200 °C
    temperature at analyzer inlet
    Давление процесса: 900 ... 1,100 hPa
    Ambient temperature: With cooling device: +5 ... +50 °C
    Standard: +5 ... +35 °C
    Ambient pressure: 900 ... 1,100 bar
    Ambient humidity: 0 ... 80 %
    relative humidity; non-condensing
    Conformities: 2000/76/EC
    2001/80/EC
    27. BImSchV
    EN 14181
    EN 15267
    Electrical safety: CE
    Enclosure rating: IP 43
    Optional: IP 54
    Analog outputs: Outputs:
    0/4 ... 22 mA, 500 Ω number depends on system configuration; electrically isolated; max. 32 outputs
    Analog inputs: Inputs:
    0/4 ... 22 mA, 100 Ω number depends on system configuration; electrically isolated; max. 32 inputs
    Digital outputs: Outputs:
    48 V AC, 0.5 A, 35 VA / 48 V DC, 0.5 A, 24 Wnumber depends on system configuration; electrically isolated; max. 64 outputs
    Digital inputs: Inputs:
    3.9 V, 4.5 mA, 0.55 W number depends on system configuration; max. 64 inputs
    Interfaces: Ethernet
    RS-422/RS-485
    Bus protocol: Ethernet TCP/IP
    Modbus
    OPC
    Operation: Several operating levels, password-protected, Via LC-display or software SOPAS ET
    System components: Analyzer
    I/O module
    Control unit
    Temperature control unit
    Test functions: Internal zero point check
    Corrective functions: Internal adjustment unit (option)
     
     

     
     
     