Air quality tunnel sensor, VISIC100SF

 
 

The VISIC100SF tunnel sensor is an all-in-one solution for measuring visibility, CO, and NO concentrations. It is the only product of its kind in the world to combine the scattered light measurement principle with electrochemical cells - all in one compact housing. The VISIC100SF is very easy to mount, operate, and maintain. There is no need for alignment or configuration - so you can start measuring right away. With its IP6K9K enclosure rating, not only is the VISIC100SF able to withstand the harsh ambient conditions inside the tunnel; it can also endure tunnel washing operations without any problems. During the design phase, particular importance was attached to ensuring reliable operation and long maintenance intervals. To compensate for fog, there is an optional version available with heating. Thus, the VISIC100SF is an elegant solution that meets the desired requirements and is ideal for any tunnel application.

At a glance

  • Visibility (K value) measured according to the scattered light measurement principle
  • CO and NO measurement using electrochemical cells in accordance with EN 50545
  • Software developed in accordance with EN 61508 (SIL1)
  • Highly reliable (no moving parts)
  • Combines visibility measurement with two different gas measurements
  • IP6K9K enclosure rating thanks to rugged stainless steel housing
  • Fog compensation thanks to integrated heating (option)

    Your benefits

  • One sensor for three measuring components
  • High levels of availability and operational safety
  • No protective measures required for tunnel washing
  • No impairment of ventilator control when tunnel portal is shrouded in fog
  • Flexible connection options and easy to extend, can be easily integrated into existing networks
  • Visibility measurement can be easily verified wih checking tool
  • Low level of effort required thanks to easy mounting and quick commissioning

    Fields of application

  • For monitoring visibility plus CO and/or NO concentrations in road tunnels for the purpose of ventilator control
  • For the selective measurement of visibility when the tunnel portal is shrouded in fog
  • In railroad tunnels (on request)
  • Anywhere where air quality has to be measured and improved
    Technical data
    Measurement principles: Electrochemical cell, Scattered light forward
    Max. number of measurands: 3
    Measured values: Visibility (K-value), CO, NO
    Measuring ranges: Visibility (K-value): 0 ... 15 /km
    CO: 0 ... 300 ppm
    NO: 0 ... 100 ppm
    Ambient temperature: -20 ... +55 °C
    Ambient pressure: 860 ... 1,080 hPa
    Ambient humidity: 10 ... 100 %
    relative humidity; non-condensing
    Conformities: RABT 2006
    RVS 09.02.22
    ASTRA "Guideline - Ventilation of Road Tunnels" (2008)
    EN 50545
    EN 61508 (SIL 1)
    Electrical safety: CE
    Enclosure rating: Sensor unit, terminal box: IP 6K9K
    TAD tunnel adapter device: IP 66
    Analog outputs: 3 outputs:
    4 ... 20 mA, 500 Ω
    electrically isolated; short-circuit proof
    Digital outputs: 2 relay contacts:
    48 V DC, 0.5 A, 24 W
    preset for failure and maintenance request
    Interfaces: RS-485
    Bus protocol: Modbus RTU
    PROFIBUS DP (option)
    Operation: Via LC-display and function keys
    Test functions: Automatic self-test
    Drift and plausibility check
    Functional monitoring of the optional heating
    Contamination monitoring of glass pane
    Mounting: Wall-mounting, vertical, up to a wall inclination of 45°
    Options: CO sensor, Internal heating, NO sensor, Terminal box, TAD tunnel adapter device
     
     

     
     
     