At a glance
Collision protection, person protection and navigation support in one device |
7 m protective field range |
15 m collision protection field range |
Can only be used in EFI system network with modular Flexi Soft safety controller |
Up to 16 switchable field sets |
Configuration memory integrated in the system plug |
Extended measurement data output via RS-422 with landmark recognition |
Your benefits
Increases your productivity: Using collision protection you can operate two vehicles in one narrow aisle at the same time. |
The largest field range in the market allows for high velocity of the vehicles and therefore high productivity. |
Three functions in one device: person protection, safe collision protection and navigation support with landmark recognition |
High availability of the complete system thanks to velocity dependent field set switching of up to 16 field sets |
Quick recommissioning via configuration memory |
Applications | |||
Hazardous area protection (vertical): | - | ||
Access protection (vertical): | - | ||
Hazardous area protection (horizontal): | ![]() |
Functions | |||
Number of simultaneously monitored protective fields: | 2 1) | ||
Static protective field switching: | ![]() |
||
Incremental encoder inputs: | ![]() |
||
External device monitoring (EDM): | ![]() |
||
Integrated configuration memory: | ![]() |
||
Expanded measured data output (CMS): | ![]() |
||
Measured data output: | ![]() |
||
Safe SICK device communication via EFI/SDL: | ![]() |
Technical data | |||
Laser class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) | ||
Enclosure rating: | IP 65 (EN 60529) | ||
Класс защиты: | II (EN 50178) | ||
Type: | Type 3 (IEC 61496) | ||
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) | ||
Category: | Category 3 (EN ISO 13849) | ||
Уровень производительности: | PL d (EN ISO 13849) | ||
PFHd: | 8.0 * 1E-08 (EN ISO 13849) | ||
TM (mission time): | 20 a (EN ISO 13849) | ||
Ambient operating temperature: | -10 °C ... +50 °C | ||
Dimensions (W x H x D): | 155 mm x 185 mm x 160 mm | ||
Вес: | 3.3 kg | ||
Scan angle: | 190 ° | ||
Protective field range: | 7 m | ||
Collision protection field range: | 15 m (on reference target) 1) | ||
Количество устанавливаемых полей: | 16 2) | ||
Type of field set: | Dual field sets, Triple field sets | ||
Number of monitoring cases: | 32 | ||
Response time: | 120 ms 3) | ||
Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable | ||
Distance measuring range: | 49 m | ||
Число многократных выборок: | Configurable 2 ... 16 | ||
Electrical connection: | System plug with or without connecting cable | ||
Supply voltage: | 16.8 V DC, 24 V DC, 28.8 V DC | ||
Кол-во EDM выходов: | 1 | ||
Rол-во входов сброса/перезапуска: | 1 | ||
Количество статических управляющих входов с EFI: | 5 4) | ||
Количество безопасных выходов: | 2, Safety outputs (OSSD) | ||
Количество применимых диагностических выходов: | 3 5) | ||
Maximum output current: | 500 mA | ||
Configuration and diagnostics interface: | RS-232 | ||
Интерфейс передачи данных: | RS-422 |