The product family FLOWSIC100 was designed for emission monitoring tasks. The "H" versions are suitable for stacks with large diameters and applications with high dust content. The "M" versions are especially suited for stacks with medium diameter. The ultrasonic transducers of the "PR" probe type are mounted with fixed path length on one sender/receiver unit (measuring probe). The "AC" versions have an innovative internal cooling and are suitable for gas temperatures up to 450 °C. The purged "Px" versions are used for gases with high concentrations of sticky or wet dust.
Rugged titanium transducers are standard and suitable under difficult conditions. The measuring system consists of 2 sender/receiver units or a measuring probe and a MCU control unit. The MCU is used for input and output of signals, for calculation of volume flow to reference conditions (standardization) as well as user-friendly LCD interface.
At a glance
Rugged titanium transducers for high durability |
Corrosion-resistant material for application in aggressive gases (option) |
Integral measurement over the duct diameter with types H, M and S |
Probe type PR for economic installation from one side of the duct |
Automatic function control with zero and span point check |
Your benefits
Reliable flow measurement for ducts with small up to very large diameters |
High durability of the device |
Minimum operating and maintenance costs |
Accurate measuring results under difficult measuring conditions |
Measurement without pressure loss, therefore no influences on the process |
User-friendly operation via SOPAS ET software |
Reliable function monitoring due to enhanced diagnosis |
No purge air required for applications with gas temperatures up to 260 °C |
Fields of application
Continuous emission measurements in power generation |
Emission monitoring in waste incineration plants |
Emission measurement in processing industries (cement, iron and steel, glass) |
Emission monitoring in chemical and petrochemical industry |
Emission monitoring in paper and textile industry |
Flow measurement and process control e.g. in heating and ventilation plants |
Technical data | |||
Max. number of measurands: | 1 | ||
Measured values: | Gas velocity, Gas temperature, Sound velocity, Volumetric flow, a. c., Volumetric flow s. c. | ||
Measurement principle: | Ultrasonic transit time difference measurement | ||
Measuring ranges: | Gas velocity: 0 ... ± 40 m/s | ||
Diagnostics functions: | Automatic check cycle for zero and span point Extended device diagnosis via SOPAS ET software |
||
Температура процесса: | -40 ... +450 °C depending on device version |
||
Давление процесса: | -100 ... 100 hPa | ||
Nominal pipe size: | 0.15 ... 13 m depending on device version |
||
Dust load: | ≤100 g/m3 depending on device version, measuring path, gas temperature and dust properties |
||
Ambient temperature: | FLSE100 sender/receiver units , MCU control unit: -40 ... +60 °C | ||
Conformities: | 2000/76/EC 2001/80/EC 27. BImSchV 30. BImSchV EN 14181 EN 15267 EN 16911-2 GOST MCERTS German Clean Air Regulations |
||
Electrical safety: | CE | ||
Enclosure rating: | IP 65 | ||
Analog outputs: | 1 output: 0/2/4 ... 20 mA, 750 Ω electrically isolated; up to five outputs when using additional modules (option) |
||
Analog inputs: | 2 inputs: 0 ... 20 mA up to four outputs when using additional modules (option) |
||
Digital outputs: | 5 relay outputs (change-over contacts), potential-free: 48 V, 1 A safety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning", "maintenance" and "check cycle" |
||
Digital inputs: | 4 potential-free contacts |
||
Interfaces: | RS-232 (via clamp terminal; service interface) RS-485 (for connection of sender/receiver unit(s)) USB 1.1 (virtual COM port; service interface) |
||
Bus protocol: | Ethernet TCP/IP (via optional interface module) Modbus (via optional interface module) Modbus TCP (via optional interface module) PROFIBUS DP (via optional interface module) |
||
Operation: | Via LC-display or software SOPAS ET | ||
Device version: | Cross-duct version Measuring probe version |
||
System components: | Connection unit Flange(s) with tube FLSE100 sender/receiver units MCU control unit |
||
Mounting: | Installation angle 45° (probe version) Installation angle 45° ... 60° |