Volume flow measuring device for emission monitoring, FLOWSIC100

 
 

The "High Power" FLOWSIC100 H version with high ultrasound power is suitable for measurements in stacks with large diameters as well as for applications with high dust content. The FLOWSIC100 M with medium acoustic power is especially suited for stacks with medium diameter. The ultrasonic transducers of the probe type FLOWSIC100 PR are mounted with fixed path length on one sender/receiver unit (measuring probe). This probe version requires installation from only one side of the duct with minimal effort. It enables installation in facilities with access from only one side.

Rugged titanium transducers are standard and suitable under difficult conditions. The measuring system needs no purge air and consists of 2 sender/receiver units and a MCU control unit. The MCU is used for input and output of signals, for calculation of volume flow to reference conditions (standardization) as well as user-friendly LCD interface.

At a glance

  • Rugged titanium transducers for high durability
  • Measuring system without purge air
  • Corrosion-resistant material for application in aggressive gases (option)
  • Integral measurement over the duct diameter with types H, M and S
  • Probe type PR for economic installation from one side of the duct
  • Automatic function control with zero and span point check

    Your benefits

  • Reliable flow measurement for ducts with small up to very large diameters
  • High durability of the device
  • Very low operating and maintenance costs due to operation without purge air
  • Accurate measuring results under difficult measuring conditions
  • Measurement without pressure loss, therefore no influences on the process
  • User-friendly operation via SOPAS ET software
  • Reliable function monitoring due to enhanced diagnosis

    Fields of application

  • Continuous emission measurements in power generation
  • Emission monitoring in waste incineration plants
  • Emission measurement in processing industries (cement, iron and steel, glass)
  • Emission monitoring in chemical and petrochemical industry
  • Emission monitoring in paper and textile industry
  • Flow measurement and process control e.g. in heating and ventilation plants
    Technical data
    Measurement principle: Ultrasonic transit time difference measurement
    Measured values: Gas velocity
    Gas temperature
    Sound velocity
    Volumetric flow, a. c.
    Volumetric flow s. c.
    Max. number of measurands: 1
    Measuring ranges: Gas velocity: -40 ... 0 m/s / 0 ... 40 m/s
    Comment: Continuously adjustable
    Температура процесса: FLOWSIC100 M/H/PR: -40 ... +260 °C
    versions for lower temperatures on request
    FLOWSIC100 S: -40 ... +150 °C
    versions for lower temperatures on request
    Давление процесса: -100 ... 100 hPa
    Dust load: FLOWSIC100 H: ≤10 g/m3
    depending on measuring path and gas temperature; for dry, non-sticky dust
    FLOWSIC100 M/S/PR: ≤1 g/m3
    Nominal pipe size: FLOWSIC100 H: 1.4 ... 13 m
    FLOWSIC100 M: 0.16 ... 3.4 m
    FLOWSIC100 PR: ≥0.4 m
    FLOWSIC100 S: 0.15 ... 1.7 m
    Length of measuring path: FLOWSIC100 H (hastelloy version): 2 ... 5 m
    FLOWSIC100 H: 2 ... 15 m
    FLOWSIC100 M (hastelloy version): 0.2 ... 2 m
    FLOWSIC100 M: 0.2 ... 4 m
    FLOWSIC100 PR: ≤0.28 m
    fixed measuring distance
    FLOWSIC100 S: 0.2 ... 2 m
    Ambient temperature: FLSE100 sender/receiver units , MCU control unit: -40 ... +60 °C
    Conformities: 2000/76/EC
    2001/80/EC
    27. BImSchV
    EN 14181
    EN 15267
    German Clean Air Regulations
    Electrical safety: CE
    Enclosure rating: IP 65
    Analog outputs: 1 output:
    0/2/4 ... 22 mA, 750 Ω
    additional outputs if using I/O modules
    Analog inputs: 2 inputs:
    0 ... 20 mA , 0 ... 10 V
    additional inputs if using I/O modules
    Digital outputs: 5 floating outputs (change-over contacts) 48 V, 1 A
    additional outputs if using I/O modules
    Digital inputs: 4 potential-free contacts
    additional inputs if using I/O modules
    Interfaces: Ethernet (option)
    RS-232 (service interface)
    RS-485 (option)
    USB 1.1
    Bus protocol: Ethernet TCP/IP (option)
    Modbus (option)
    PROFIBUS DP (option)
    Operation: Via LC-display or software SOPAS ET
    Device version: Cross-duct version, Measuring probe version
    System components: Connection unit
    Flange(s) with tube
    FLSE100 sender/receiver units
    MCU control unit
    Diagnostics functions: Automatic check cycle for zero and span point
    Extended device diagnosis via SOPAS ET software
    Mounting: Installation angle 45° (probe version), Installation angle 45° ... 60°
     