The "High Power" FLOWSIC100 H version with high ultrasound power is suitable for measurements in stacks with large diameters as well as for applications with high dust content. The FLOWSIC100 M with medium acoustic power is especially suited for stacks with medium diameter. The ultrasonic transducers of the probe type FLOWSIC100 PR are mounted with fixed path length on one sender/receiver unit (measuring probe). This probe version requires installation from only one side of the duct with minimal effort. It enables installation in facilities with access from only one side.
Rugged titanium transducers are standard and suitable under difficult conditions. The measuring system needs no purge air and consists of 2 sender/receiver units and a MCU control unit. The MCU is used for input and output of signals, for calculation of volume flow to reference conditions (standardization) as well as user-friendly LCD interface.
At a glance
Rugged titanium transducers for high durability |
Measuring system without purge air |
Corrosion-resistant material for application in aggressive gases (option) |
Integral measurement over the duct diameter with types H, M and S |
Probe type PR for economic installation from one side of the duct |
Automatic function control with zero and span point check |
Your benefits
Reliable flow measurement for ducts with small up to very large diameters |
High durability of the device |
Very low operating and maintenance costs due to operation without purge air |
Accurate measuring results under difficult measuring conditions |
Measurement without pressure loss, therefore no influences on the process |
User-friendly operation via SOPAS ET software |
Reliable function monitoring due to enhanced diagnosis |
Fields of application
Continuous emission measurements in power generation |
Emission monitoring in waste incineration plants |
Emission measurement in processing industries (cement, iron and steel, glass) |
Emission monitoring in chemical and petrochemical industry |
Emission monitoring in paper and textile industry |
Flow measurement and process control e.g. in heating and ventilation plants |
Technical data | |||
Measurement principle: | Ultrasonic transit time difference measurement | ||
Measured values: | Gas velocity Gas temperature Sound velocity Volumetric flow, a. c. Volumetric flow s. c. |
||
Max. number of measurands: | 1 | ||
Measuring ranges: | Gas velocity: -40 ... 0 m/s / 0 ... 40 m/s | ||
Comment: | Continuously adjustable | ||
Температура процесса: | FLOWSIC100 M/H/PR: -40 ... +260 °C versions for lower temperatures on request FLOWSIC100 S: -40 ... +150 °C versions for lower temperatures on request |
||
Давление процесса: | -100 ... 100 hPa | ||
Dust load: | FLOWSIC100 H: ≤10 g/m3 depending on measuring path and gas temperature; for dry, non-sticky dust FLOWSIC100 M/S/PR: ≤1 g/m3 |
||
Nominal pipe size: | FLOWSIC100 H: 1.4 ... 13 m FLOWSIC100 M: 0.16 ... 3.4 m FLOWSIC100 PR: ≥0.4 m FLOWSIC100 S: 0.15 ... 1.7 m |
||
Length of measuring path: | FLOWSIC100 H (hastelloy version): 2 ... 5 m FLOWSIC100 H: 2 ... 15 m FLOWSIC100 M (hastelloy version): 0.2 ... 2 m FLOWSIC100 M: 0.2 ... 4 m FLOWSIC100 PR: ≤0.28 m fixed measuring distance FLOWSIC100 S: 0.2 ... 2 m |
||
Ambient temperature: | FLSE100 sender/receiver units , MCU control unit: -40 ... +60 °C | ||
Conformities: | 2000/76/EC 2001/80/EC 27. BImSchV EN 14181 EN 15267 German Clean Air Regulations |
||
Electrical safety: | CE | ||
Enclosure rating: | IP 65 | ||
Analog outputs: | 1 output: 0/2/4 ... 22 mA, 750 Ω additional outputs if using I/O modules |
||
Analog inputs: | 2 inputs: 0 ... 20 mA , 0 ... 10 V additional inputs if using I/O modules |
||
Digital outputs: | 5 floating outputs (change-over contacts) 48 V, 1 A additional outputs if using I/O modules |
||
Digital inputs: | 4 potential-free contacts additional inputs if using I/O modules |
||
Interfaces: | Ethernet (option) RS-232 (service interface) RS-485 (option) USB 1.1 |
||
Bus protocol: | Ethernet TCP/IP (option) Modbus (option) PROFIBUS DP (option) |
||
Operation: | Via LC-display or software SOPAS ET | ||
Device version: | Cross-duct version, Measuring probe version | ||
System components: | Connection unit Flange(s) with tube FLSE100 sender/receiver units MCU control unit |
||
Diagnostics functions: | Automatic check cycle for zero and span point Extended device diagnosis via SOPAS ET software |
||
Mounting: | Installation angle 45° (probe version), Installation angle 45° ... 60° |