The Flow-X flow computer provides gas volume conversion, event logging, audit trails and reports using latest technology. Each module combines advanced measurement technology, fast digital signal processing, abundant processing power, versatile data communication and high capacity storage into a fully equipped flow computer. Stream modules are combined in different enclosures, offering a multi-stream version Flow-X/P for 1 - 4 streams with local touch screen or a single stream version Flow-X/S for smaller installations with one stream. The Flow-X flow computer meets the requirements for even the most demanding applications and is the ideal partner for custody gas metering solutions in installations with FLOWSIC600 ultrasonic gas meters.

At a glance

  • MID approved configuration for gas metering streams with FLOWSIC600
  • Powerful modules for demanding applications
  • Each module features CPU, memory and equal in/outputs
  • Compelling 7" graphic display with touch operation
  • Intuitive user interface for graphics display and web browser
  • True remote access via Ethernet
  • Station computer for multiple streams

    Your benefits

  • Reduced planning and installation costs through standard configurations
  • Very accurate volume conversion with multiple calculation cycles per second
  • High reliability through independent modules with their own volume conversion and storage of measured values, counter readings and events
  • Easy extension of installations with modules featuring equal in/outputs and 100% software configuration
  • Very simple operation through intuitive user interface featuring identical menus and displays on the device and in the control room
  • Reduced service and maintenance costs with tamper-proof remote maintenance
  • Cost-efficient and flexible system integration of multiple streams

    Fields of application

  • Custody gas metering with FLOWSIC600 gas meters
  • Demanding natural gas and process gas applications
  • Totals at base conditions for gas volume, mass and energy
  • For natural gas, special gases and steam
  • Gas metering with advanced diagnostics with FLOWSIC600 2plex
  • Redundant gas metering with FLOWSIC600 Quatro
    Technical data
    Ambient temperature: +5 ... +55 °C
    Ambient humidity: ≤90 %
    relative humidity; non-condensing
    Conformities: API 21.1
    MID
    Analog outputs: 4 outputs:
    0/4 ... 20 mA , 1 ... 5 V
    Resolution 14 bits; 0.075 % full scale.
    Analog inputs: 6 inputs, configurable as:
    0/4 ... 20 mA , 0 ... 5 V
    HART loop for connection to HART transmitters on four analog inputs. Inputs with high accuracy: error
    Digital inputs and outputs: 16 Open collector ports:
    software configured as status inputs or outputs
    Additional inputs: 2 PRT (RTD) inputs for PT100 temperature sensors: -220 ... +220 °C
    Resolution 0.02 °C
    Maximum error:
    0 ... +50 °C: +0.05 °C
    -220 ... +220 °C: +0.5 °C
    Interfaces: 2 x RJ45 (Ethernet TCP/IP 100 MBit/s)
    2 x RS-232
    Correction method: PTZ
    Compressibility: AGA 10
    AGA 8 (detailed)
    AGA 8 Gross methods
    AGA NX-19
    SGERG
    Supported gas chromatographs: Supports all major gas chromatographs (e.g. ABB, Daniel, Elster, Siemens)
    Components CPU board: 400 MHz i.MX processor with math coprocessor and FPGA
    50 MB RAM
    32 MB Flash memory
    Real time clock with internal lithium cell; accuracy better than 1s/day
     

    The Flow-X flow computer provides gas volume conversion, event logging, audit trails and reports using latest technology. Each module combines advanced measurement technology, fast digital signal processing, abundant processing power, versatile data communication and high capacity storage into a fully equipped flow computer. Stream modules are combined in different enclosures, offering a multi-stream version Flow-X/P for 1 - 4 streams with local touch screen or a single stream version Flow-X/S for smaller installations with one stream. The Flow-X flow computer meets the requirements for even the most demanding applications and is the ideal partner for custody gas metering solutions in installations with FLOWSIC600 ultrasonic gas meters.

    At a glance

  • MID approved configuration for gas metering streams with FLOWSIC600
  • Powerful modules for demanding applications
  • Each module features CPU, memory and equal in/outputs
  • Compelling 7" graphic display with touch operation
  • Intuitive user interface for graphics display and web browser
  • True remote access via Ethernet
  • Station computer for multiple streams

    Your benefits

  • Reduced planning and installation costs through standard configurations
  • Very accurate volume conversion with multiple calculation cycles per second
  • High reliability through independent modules with their own volume conversion and storage of measured values, counter readings and events
  • Easy extension of installations with modules featuring equal in/outputs and 100% software configuration
  • Very simple operation through intuitive user interface featuring identical menus and displays on the device and in the control room
  • Reduced service and maintenance costs with tamper-proof remote maintenance
  • Cost-efficient and flexible system integration of multiple streams

    Fields of application

  • Custody gas metering with FLOWSIC600 gas meters
  • Demanding natural gas and process gas applications
  • Totals at base conditions for gas volume, mass and energy
  • For natural gas, special gases and steam
  • Gas metering with advanced diagnostics with FLOWSIC600 2plex
  • Redundant gas metering with FLOWSIC600 Quatro
    Technical data
    Ambient temperature: +5 ... +55 °C
    Ambient humidity: ≤90 %
    relative humidity; non-condensing
    Conformities: API 21.1
    EN 12405
    MID
    Analog outputs: 4 outputs:
    0/4 ... 20 mA , 1 ... 5 V
    Resolution 14 bits; 0.075 % full scale.
    Analog inputs: 6 inputs, configurable as:
    0/4 ... 20 mA , 0 ... 5 V
    HART loop for connection to HART transmitters on four analog inputs. Inputs with high accuracy: error
    Digital inputs and outputs: 16 Open collector ports:
    software configured as status inputs or outputs
    Additional inputs: -220 ... +220 °C: +0.5 °C
    0 ... +50 °C: +0.05 °C
    2 PRT (RTD) inputs for PT100 temperature sensors: -220 ... +220 °C
    Resolution 0.02 °C
    Maximum error
    Interfaces: 2 x RJ45 (Ethernet TCP/IP 100 MBit/s)
    2 x RS-232/RS-485
    Correction method: PTZ
    Compressibility: AGA 8 (detailed)
    AGA 8 Gross methods
    AGA NX-19
    SGERG
    Supported gas chromatographs: Supports all major gas chromatographs (e.g. ABB, Daniel, Elster, Siemens)
    Components CPU board: 32 MB Flash memory
    400 MHz i.MX processor with math coprocessor and FPGA
    50 MB RAM
    Real time clock with internal lithium cell; accuracy better than 1s/day
     
     

     
     
     