The Combiprobe CP100 is the combination of a DUSTHUNTER SP100 scattered light dust measuring device and a FLOWSIC100 PR volume flow measuring device on a flange plate. The combined probe also features a pressure transmitter and a resistance thermometer. The Combiprobe CP100 only requires a single mounting opening in the funnel in order to measure the dust concentration, volume flow, pressure and temperature. This means that there is considerably less outlay on installation than if the individual components were to be installed separately.
At a glance
No need for mechanical adjustment |
Self-testing with the automatic control cycle |
Simple configuration and operation with easy-to-use software |
For gas temperatures up to 200 °C |
For funnels with an internal diameter of 0.7Â m and above |
Your benefits
Easy to install complete solution for detecting dust emission and the emission-related benchmarks of volume flow, pressure and temperature |
Low operating costs due to the measuring devices' long maintenance intervals |
Durable and reliable components |
Scattered light dust measuring device and volume flow measuring device that have been performance-tested according to EN 15267 |
Fields of application
Emission monitoring in power stations |
Emission measurement during waste incineration |
Emission measurement within the cement and steel industry |
Process measurement in processing plants within the pharmaceutical, food and animal feed industries |
Monitoring of heat treatment and extraction systems |
Process monitoring within the chemical industry |
Technical data | |||
Measurement principles: | Scattered light forward, Ultrasonic transit time difference measurement | ||
Measured values: | Gas pressure, Gas velocity, Gas temperature, Dust concentration (after gravimetric comparison measurement) | ||
Max. number of measurands: | 4 | ||
Measuring ranges: | Gas pressure: 800 ... 1,200 hPa Gas velocity: 0 ... ± 40 m/s Gas temperature: -50 ... +400 °C Dust concentration: 0 ... 5 mg/m3 / 0 ... 200 mg/m³ |
||
Температура процесса: | -20 ... +200 °C | ||
Давление процесса: | -70 ... 10 hPa | ||
Process gas humidity: |
non-condensing |
||
Duct diameter: | ≥700 mm | ||
Ambient temperature: | -20 ... +60 °C Intake temperatures for purge air: -20 ... +45 °C |
||
Electrical safety: | CE | ||
Enclosure rating: | Pressure sensor, temperature sensor: IP 54 DUSTHUNTER SP100: IP 66 FLOWSIC100 PR: IP 65 |
||
Analog outputs: | 3 outputs: 0/2/4 ... 22 mA, 750 Ω electrically isolated; two additional outputs if using I/O modules (option) |
||
Analog inputs: | 2 inputs: 0 ... 20 mA not electrically isolated; two additional inputs if using I/O modules (option) |
||
Digital outputs: | 5 relay contacts: 48 V, 1 A potential-free; for status signals |
||
Digital inputs: | 4 potential-free contacts |
||
Interfaces: | RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) USB (service interface) |
||
Bus protocol: | Ethernet TCP/IP (via optional interface module) PROFIBUS DP (via optional interface module) |
||
Operation: | Via LC-display or software SOPAS ET | ||
System components: | Pressure sensor DUSTHUNTER SP100 FLOWSIC100 PR Combined flange system MCU-P control unit Temperature sensor |
||
Mounting: | Single mounting point on the duct |