Measuring device for NO, NO2 and visibility, VICOTEC320

Главная » Продукция » SICK » Датчики дорожного движения » Measuring device for NO, NO2 and visibility, VICOTEC320
 
 

The VICOTEC320 measures very small concentrations of NO2 and NO as well as the visibility and temperature in road tunnels simultaneously and fast using proven components without test gases for zero and reference point. An automatic, cyclic adjustment of zero and reference point ensures correct values. The robust enclosure withstands thorough tunnel cleanings without problems. Product requires minimal upkeep: maintenance and cleaning once a year.

The VICOTEC320 can be optionally equipped with an electrochemical cell for CO measurement. This is useful to perform the plausibility checks which some tunnel standards (e.g. German RABT2006) recommend - even when NO2 is measured as lead gas component.

At a glance

  • Very low detection limits for NO and NO2
  • Automatic function monitoring and self-adjustment
  • Very sturdy design in stainless steel
  • Automatic beam alignment between sender/receiver unit and reflector

    Your benefits

  • Energy and cost savings for ventilation control due to very low zero offset and accurate measurement
  • Low operational costs because no air aspiration system, no test gases and no ambient air required
  • Low maintenance requirements due to long maintenance interval (1 year)

    Fields of application

  • Monitoring of air quality in road tunnels
  • Ventilaton control and filter monitoring in tunnels
    Technical data
    Measurement principles: Differential optical absorption spectroscopy (DOAS), Electrochemical cell, Pt1000, Transmittance measurement
    Max. number of measurands: 5
    Measuring ranges: NO: 0 ... 20 ppm / 0 ... 45 ppm
    CO: 0 ... 100 ppm / 0 ... 300 ppm
    NO2: 0 ... 1 ppm / 0 ... 5 ppm
    Visibility: 0 ... 15 /km / 0 ... 99 /km
    Temperature: -25 ... +55 °C
    Length of measuring path: 10 ... 20 m
    Ambient temperature: -25 ... +55 °C
    CO sensor: -20 ... +40 °C
    Ambient pressure: 700 ... 1,200 hPa
    Ambient humidity: 10 ... 95 %
    relative humidity; non-condensing
    Electrical safety: CE
    Enclosure rating: IP 66
    MCU control unit: IP 69K
    Analog outputs: 4 outputs:
    0 ... 20 mA, 500 Ω
    6 outputs if CO is measured
    Digital outputs: 4 relay contacts
    6 outputs if CO is measured; three outputs preset for fault, maintenance and functional check
    Digital inputs: 1 input
    preset for maintenance mode
    Interfaces: RS-232 (service interface)
    RS-485
    Interface module
    USB (service interface)
    Bus protocol: CAN (option)
    Ethernet
    Operation: Via LC-display
    System components: Connection unit
    Reflector unit
    Sender/receiver unit
    Test functions: Manual linearity check
    Contamination check
    Corrective functions: Automatic adjustment
     
     

     
     
     
    Имя Отчество:
     
    Адрес электронной почты:
     
    Контактный телефон:
     
    Наименование компании:
     
    Содержание заказа: