+7 (812) 432-38-38
+7 (812) 432-36-36
Пн-Пт 9:00 — 18:00
 
Заказать оборудование
 

EMSS 5-pin

 
 
Арт. 1061711

At a glance

  • Ability to cascade 32 sensors with up to 30 m per segment in compliance with performance level e
  • Compatible with sensors from all manufacturers
  • Detailed diagnostic information
  • Integrated standard inputs and outputs
  • Power supply for sensors is included
  • Unscreened standard cable with M12 connectivity
  • IP 65 and IP 67 enclosure rating
  • Intelligent accessories for field diagnostics and commissioning

    Your benefits

  • Cascading of safety switches and safety sensors with OSSD outputs minimizes the wiring effort and the number of inputs of the safety controller, which saves costs
  • Easy retrofitting of existing machines
  • Simple calculation of the performance level saves time since the Flexi Loop node monitors each sensor individually
  • User-friendly due to quick and easy configuration
  • Ability to be used over long distances increases application flexibility
  • Detailed diagnostic information minimizes system downtime
  • Seamless system integration and communication with other SICK safety controllers
  • Detailed status information on Flexi Loop components, diagnostics accessories, and safety controller enable quick and easy field diagnostics
    Safety-related parameters
    Safety integrity level: SIL3 (IEC 61508)
    SILCL3 (EN 62061)
    Category: Category 4 (EN ISO 13849-1)
    Уровень производительности: PL e (EN ISO 13849-1)
    PFHd: 0.76 * 1E-09 (EN ISO 13849)
    TM (mission time): 20 a (EN ISO 13849)
    Safe state in the event of a fault: The sensor cascade has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit.
    Functions
    Cross-circuit: Monitoring via Flexi Loop node
    Short-circuit: Monitoring via Flexi Loop node
    Расхождение ошибки: Monitoring via Flexi Loop node
    Sequence errors: Monitoring via Flexi Loop node
    Mechanical data
    Dimensions (W x H x D): 68.15 mm x 45 mm x 18 mm
    Вес: 28 g (± 5 %)
    Electrical data
    Класс защиты: III (EN 61140)
    Type of supply voltage: SELV
    Supply voltage Vs: 24 V DC (16.8 V DC ... 30 V DC)
    Потребляемая мощность: 55 mA
    Interfaces
    Safety device connection: Dual-channel equivalent electro-mechanical safety switch (EMSS)
    Flexi Loop вход: To connect a Flexi Loop predecessor module, or to connect a Flexi Loop string with the safety controller Flexi Soft.
    Flexi Loop выход: To connect a Flexi Loop successor module, or to terminate a Flexi Loop string with the Flexi Loop termination element.
    Connection type safety device: Female connector M12, 5-pin
    Connection type Flexi Loop input: Connector M12, 5-pin
    Connection type Flexi Loop output: Female connector M12, 5-pin
    Number of non-safe inputs: 0
    Number of non-safe outputs: 0
    Power supply output for external devices: -
    IO-Link: -
    Данные окуражающей среды
    Enclosure rating: IP 65, IP 67 (EN 60529)
    Ambient operating temperature: -25 °C ... +55 °C
    Storage temperature: -25 °C ... +70 °C
    Electromagnetic compatibility (EMC): Class A (EN 61000-6-2, EN 55011)
    Shock resistance (continuous shock): 10 g, 16 ms (EN 60068-2-64)
    Shock resistance (single shock): 30 g, 11 ms (EN 60068-2-27)
     
     

     
     
     
    Имя Отчество:
     
    Адрес электронной почты:
     
    Контактный телефон:
     
    Наименование компании:
     
    Содержание заказа: