At a glance
For installation at sites with limited space |
The smooth sleeve is simply secured by a setscrew |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Тип устройства: | Fibers | ||
Jacket material: | Chrome-plated helical metal spring with PVC sheathing | ||
Core material: | Glass fiber | ||
Mounting sleeve dimension: | Ø 5,8 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 20 mm | ||
Ambient operating temperature: | -10 °C ... +60 °C | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | |||
Dimensions end sleeve: | Ø 4 mm | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Smooth sleeve | ||
Fiber length: | 450 mm | ||
Волоконно-оптические датчики: | WLL170(T)-2, WLL180T, WLL190T-2 |
At a glance
For installation at sites with limited space |
The smooth sleeve is simply secured by a setscrew |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Тип устройства: | Fibers | ||
Jacket material: | Chrome-plated helical metal spring with PVC sheathing | ||
Core material: | Glass fiber | ||
Mounting sleeve dimension: | Ø 5,8 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 20 mm | ||
Ambient operating temperature: | -10 °C ... +60 °C | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | |||
Dimensions end sleeve: | Ø 4 mm | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Smooth sleeve | ||
Fiber length: | 750 mm | ||
Волоконно-оптические датчики: | WLL170(T)-2, WLL180T, WLL190T-2 |
At a glance
Space-saving installation |
Axial cable outlet is available which prevents loops and potential damage to the cable |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Тип устройства: | Fibers | ||
Jacket material: | Chrome-plated helical metal spring with PVC sheathing | ||
Core material: | Glass fiber | ||
Mounting sleeve dimension: | 19 mm x 13 mm x 7,5 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 20 mm | ||
Ambient operating temperature: | -10 °C ... +60 °C | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | |||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | 90° deflection, Smooth sleeve | ||
Fiber length: | 150 mm | ||
Волоконно-оптические датчики: | WLL170(T)-2, WLL180T, WLL190T-2 |
At a glance
Space-saving installation |
Axial cable outlet is available which prevents loops and potential damage to the cable |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Тип устройства: | Fibers | ||
Jacket material: | Chrome-plated helical metal spring with PVC sheathing | ||
Core material: | Glass fiber | ||
Mounting sleeve dimension: | 19 mm x 13 mm x 7,5 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 20 mm | ||
Ambient operating temperature: | -10 °C ... +60 °C | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | |||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | 90° deflection, Smooth sleeve | ||
Fiber length: | 450 mm | ||
Волоконно-оптические датчики: | WLL170(T)-2, WLL180T, WLL190T-2 |
At a glance
Space-saving installation |
Axial cable outlet is available which prevents loops and potential damage to the cable |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Тип устройства: | Fibers | ||
Jacket material: | Chrome-plated helical metal spring with PVC sheathing | ||
Core material: | Glass fiber | ||
Mounting sleeve dimension: | 19 mm x 13 mm x 7,5 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 20 mm | ||
Ambient operating temperature: | -10 °C ... +60 °C | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | |||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | 90° deflection, Smooth sleeve, Tip adapters | ||
Fiber length: | 750 mm | ||
Волоконно-оптические датчики: | WLL170(T)-2, WLL180T-2, WLL190T-2 |
At a glance
Space-saving installation |
Axial cable outlet is available which prevents loops and potential damage to the cable |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Тип устройства: | Fibers | ||
Jacket material: | Chrome-plated helical metal spring with PVC sheathing | ||
Core material: | Glass fiber | ||
Mounting sleeve dimension: | 19 mm x 13 mm x 7,5 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 20 mm | ||
Ambient operating temperature: | -10 °C ... +60 °C | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | |||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | 90° deflection, Smooth sleeve | ||
Fiber length: | 450 mm | ||
Волоконно-оптические датчики: | WLL170(T)-2, WLL180T, WLL190T-2 |
At a glance
Space-saving installation |
Axial cable outlet is available which prevents loops and potential damage to the cable |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Тип устройства: | Fibers | ||
Jacket material: | Chrome-plated helical metal spring with PVC sheathing | ||
Core material: | Glass fiber | ||
Mounting sleeve dimension: | 19 mm x 13 mm x 7,5 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 20 mm | ||
Ambient operating temperature: | -10 °C ... +60 °C | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | |||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | 90° deflection, Smooth sleeve | ||
Fiber length: | 750 mm | ||
Волоконно-оптические датчики: | WLL170(T)-2, WLL180T, WLL190T-2 |
At a glance
Quick and easy mounting |
Models with hexagonal flange for trouble-free mounting with only one nut |
Optional tip adapter for a larger detection distance and small objects |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel 1) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 30 mm | ||
Heat resistance: | 70 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.5 mm 2) | ||
Конструкция жилы | Ø 1.5 mm | ||
Возможность обрезки волоконно-оптического кабеля 3): | |||
Thread sleeve: | |||
Sleeve: | - | ||
Suitable tip adaptor: | LL3-TA01, LL3-TA02 | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Standard, compact end sleeve, large sensing range | ||
Category fiber-optic cables: | Threaded sleeve | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 300 mm | ||
Operating mode 70 µs: | 950 mm | ||
Operating mode 250 µs: | 1,700 mm | ||
Operating mode 2 ms: | 3,500 mm | ||
Operating mode 8 ms: | 4,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 720 mm | ||
Greenlight 250 µs: | 280 mm | ||
Highspeed 50 µs: | 315 mm |
At a glance
Quick and easy mounting |
Models with hexagonal flange for trouble-free mounting with only one nut |
Optional tip adapter for a larger detection distance and small objects |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel 1) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 30 mm | ||
Heat resistance: | 70 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.5 mm 2) | ||
Конструкция жилы | Ø 1.5 mm | ||
Возможность обрезки волоконно-оптического кабеля 3): | |||
Thread sleeve: | |||
Sleeve: | - | ||
Suitable tip adaptor: | LL3-TA01, LL3-TA02 | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Standard, 10 m length, compact end sleeve, large sensing range | ||
Category fiber-optic cables: | Threaded sleeve | ||
Fiber length: | 10,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 230 mm | ||
Operating mode 70 µs: | 650 mm | ||
Operating mode 250 µs: | 1,200 mm | ||
Operating mode 2 ms: | 2,450 mm | ||
Operating mode 8 ms: | 4,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 420 mm | ||
Greenlight 250 µs: | 230 mm | ||
Highspeed 50 µs: | 165 mm |
At a glance
Quick and easy mounting |
Models with hexagonal flange for trouble-free mounting with only one nut |
Optional tip adapter for a larger detection distance and small objects |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel 1) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 30 mm | ||
Heat resistance: | 70 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.5 mm 2) | ||
Конструкция жилы | Ø 1.5 mm | ||
Возможность обрезки волоконно-оптического кабеля 3): | |||
Thread sleeve: | |||
Sleeve: | - | ||
Suitable tip adaptor: | LL3-TA01, LL3-TA02 | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Threaded sleeve | ||
Fiber length: | 30,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 160 mm | ||
Operating mode 70 µs: | 450 mm | ||
Operating mode 250 µs: | 840 mm | ||
Operating mode 2 ms: | 1,700 mm | ||
Operating mode 8 ms: | 2,800 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 290 mm | ||
Greenlight 250 µs: | 180 mm | ||
Highspeed 50 µs: | 110 mm |
At a glance
Quick and easy mounting |
Models with hexagonal flange for trouble-free mounting with only one nut |
Optional tip adapter for a larger detection distance and small objects |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | CuZn | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 70 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.2 mm 1) | ||
Конструкция жилы | Ø 1 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | |||
Sleeve: | - | ||
Suitable tip adaptor: | LL3-TA01, LL3-TA02 | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Standard, compact end sleeve, large sensing range | ||
Category fiber-optic cables: | Threaded sleeve | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 225 mm | ||
Operating mode 70 µs: | 650 mm | ||
Operating mode 250 µs: | 1,200 mm | ||
Operating mode 2 ms: | 2,500 mm | ||
Operating mode 8 ms: | 4,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 470 mm | ||
Greenlight 250 µs: | 135 mm | ||
Highspeed 50 µs: | 165 mm |
At a glance
Sensor tip can be positioned closely to the object |
Flexible end sleeve is available as an option |
Extremely narrow access to place of detection |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel 1) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Bend radius, end sleeve: | 10 mm | ||
Heat resistance: | 70 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.2 mm 2) | ||
Конструкция жилы | Ø 1 mm | ||
Возможность обрезки волоконно-оптического кабеля 3): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
Dimensions end sleeve: | Ø 1.5 mm | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | |||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Bendable sleeve, ideal for insufficient objects | ||
Category fiber-optic cables: | Long end sleeve | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 240 mm | ||
Operating mode 70 µs: | 700 mm | ||
Operating mode 250 µs: | 1,400 mm | ||
Operating mode 2 ms: | 2,500 mm | ||
Operating mode 8 ms: | 2,900 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 470 mm | ||
Greenlight 250 µs: | 132 mm | ||
Highspeed 50 µs: | 165 mm |
At a glance
Sensor tip can be positioned closely to the object |
Flexible end sleeve is available as an option |
Extremely narrow access to place of detection |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel | ||
Diameter, connection: | 1 mm | ||
Mounting sleeve dimension: | M3 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Bend radius, end sleeve: | 10 mm | ||
Heat resistance: | 70 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.03 mm 1) | ||
Конструкция жилы | 0.5 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | |||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Long end sleeve | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 50 mm | ||
Operating mode 70 µs: | 140 mm | ||
Operating mode 250 µs: | 250 mm | ||
Operating mode 2 ms: | 500 mm | ||
Operating mode 8 ms: | 530 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 120 mm | ||
Greenlight 250 µs: | 60 mm | ||
Highspeed 50 µs: | 60 mm |
At a glance
Space-saving installation |
Axial cable outlet is available which prevents loops and potential damage to the cable |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 70 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.05 mm 1) | ||
Конструкция жилы | 1.0 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | 90° deflection | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 150 mm | ||
Operating mode 70 µs: | 480 mm | ||
Operating mode 250 µs: | 770 mm | ||
Operating mode 2 ms: | 1,500 mm | ||
Operating mode 8 ms: | 1,600 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 400 mm | ||
Greenlight 250 µs: | 150 mm | ||
Highspeed 50 µs: | 170 mm |
At a glance
For installation at sites with limited space |
The smooth sleeve is simply secured by a setscrew |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | Ø 3 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 70 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.03 mm 1) | ||
Конструкция жилы | 1.0 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | |||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Smooth sleeve | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 180 mm | ||
Operating mode 70 µs: | 540 mm | ||
Operating mode 250 µs: | 890 mm | ||
Operating mode 2 ms: | 1,700 mm | ||
Operating mode 8 ms: | 1,900 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 400 mm | ||
Greenlight 250 µs: | 200 mm | ||
Highspeed 50 µs: | 190 mm |
At a glance
Quick and easy mounting |
Models with hexagonal flange for trouble-free mounting with only one nut |
Optional tip adapter for a larger detection distance and small objects |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | ABS | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M14 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 60 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.4 mm 1) | ||
Конструкция жилы | 1.0 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | |||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Threaded sleeve | ||
Fiber length: | 10,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 6,600 mm | ||
Operating mode 70 µs: | 19,500 mm | ||
Operating mode 250 µs: | 19,500 mm | ||
Operating mode 2 ms: | 19,500 mm | ||
Operating mode 8 ms: | 19,500 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 19,500 mm | ||
Greenlight 250 µs: | 6,000 mm | ||
Highspeed 50 µs: | 7,500 mm |
At a glance
Easy mounting |
Flush mounting in a single slot |
Background effects are minimized |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | PC | ||
Diameter, connection: | 1 mm | ||
Mounting sleeve dimension: | 7 x 10 x 2mm | ||
Радиус изгиба волоконно-оптического кабеля: | 1 mm | ||
Heat resistance: | 60 °C | ||
Ambient operating temperature: | -40 °C ... 60 °C | ||
Minimal object diameter: | 0.08 mm 1) | ||
Конструкция жилы | 151 x 0.05 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | |||
High flexible: | |||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Flat type, Flexible fiber-optic cable | ||
Fiber length: | 1,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 120 mm | ||
Operating mode 70 µs: | 350 mm | ||
Operating mode 250 µs: | 620 mm | ||
Operating mode 2 ms: | 1,250 mm | ||
Operating mode 8 ms: | 1,330 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 250 mm | ||
Greenlight 250 µs: | 120 mm | ||
Highspeed 50 µs: | 120 mm |
At a glance
Easy mounting |
Flush mounting in a single slot |
Background effects are minimized |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | PC | ||
Diameter, connection: | 1 mm | ||
Mounting sleeve dimension: | 10 x 10 x 2,5 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 1 mm | ||
Heat resistance: | 60 °C | ||
Ambient operating temperature: | -40 °C ... 60 °C | ||
Minimal object diameter: | 0.08 mm 1) | ||
Конструкция жилы | 151 x 0.05 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | |||
High flexible: | |||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Flat type, Flexible fiber-optic cable | ||
Fiber length: | 1,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 40 mm | ||
Operating mode 70 µs: | 140 mm | ||
Operating mode 250 µs: | 220 mm | ||
Operating mode 2 ms: | 450 mm | ||
Operating mode 8 ms: | 480 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 130 mm | ||
Greenlight 250 µs: | 50 mm | ||
Highspeed 50 µs: | 60 mm |
At a glance
Easy mounting |
Flush mounting in a single slot |
Background effects are minimized |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | PC | ||
Diameter, connection: | 1.3 mm | ||
Mounting sleeve dimension: | 7 x 14 x 3,5 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 1 mm | ||
Heat resistance: | 60 °C | ||
Ambient operating temperature: | -40 °C ... 60 °C | ||
Minimal object diameter: | 0.08 mm 1) | ||
Конструкция жилы | 151 x 0.075 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | |||
High flexible: | |||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Flat type, Flexible fiber-optic cable | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 190 mm | ||
Operating mode 70 µs: | 580 mm | ||
Operating mode 250 µs: | 980 mm | ||
Operating mode 2 ms: | 1,970 mm | ||
Operating mode 8 ms: | 2,100 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 500 mm | ||
Greenlight 250 µs: | 200 mm | ||
Highspeed 50 µs: | 250 mm |
At a glance
Easy mounting |
Flush mounting in a single slot |
Background effects are minimized |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | PC | ||
Diameter, connection: | 1.3 mm | ||
Mounting sleeve dimension: | 11 x 14 x 3,5 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 1 mm | ||
Heat resistance: | 60 °C | ||
Ambient operating temperature: | -40 °C ... 60 °C | ||
Minimal object diameter: | 0.03 mm 1) | ||
Конструкция жилы | 151 x 0.075 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | |||
High flexible: | |||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Flat type, Flexible fiber-optic cable | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 150 mm | ||
Operating mode 70 µs: | 440 mm | ||
Operating mode 250 µs: | 700 mm | ||
Operating mode 2 ms: | 1,400 mm | ||
Operating mode 8 ms: | 1,490 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 320 mm | ||
Greenlight 250 µs: | 120 mm | ||
Highspeed 50 µs: | 160 mm |
At a glance
Easy mounting |
Flush mounting in a single slot |
Background effects are minimized |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | PC | ||
Diameter, connection: | 1.3 mm | ||
Mounting sleeve dimension: | 11 x 8 x 3 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 4 mm | ||
Heat resistance: | 60 °C | ||
Ambient operating temperature: | -40 °C ... 60 °C | ||
Minimal object diameter: | 0.03 mm 1) | ||
Конструкция жилы | 7 x 1.25 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | |||
High flexible: | |||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Flat type, Flexible fiber-optic cable | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 150 mm | ||
Operating mode 70 µs: | 460 mm | ||
Operating mode 250 µs: | 840 mm | ||
Operating mode 2 ms: | 1,680 mm | ||
Operating mode 8 ms: | 1,780 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 350 mm | ||
Greenlight 250 µs: | 240 mm | ||
Highspeed 50 µs: | 140 mm |
At a glance
Fiber-optic cable for pipe mounting or for immersion into the liquid |
Models for immersion are made of PTFE and are therefore suitable for the food industry |
Leak detection |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PTFE | ||
Core material: | PMMA | ||
Sleeve material: | PA | ||
Diameter, connection: | 6 mm | ||
Mounting sleeve dimension: | 12 x 24 x 23 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 20 mm | ||
Heat resistance: | 60 °C | ||
Ambient operating temperature: | -20 °C ... 60 °C | ||
Возможность обрезки волоконно-оптического кабеля 1): | - | ||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | |||
Category fiber-optic cables: | Liquid level | ||
Fiber length: | 2,000 mm |
At a glance
Detection of glass substrates |
Detection of solar wafers |
Indexation in FOUP for example |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | Ø 3,7 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 70 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.06 mm 1) | ||
Конструкция жилы | 0.75 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | |||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Small 2° aperture angle | ||
Category fiber-optic cables: | 90° deflection, LCDs/transparent objects/semiconductors | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 880 mm | ||
Operating mode 70 µs: | 2,300 mm | ||
Operating mode 250 µs: | 3,500 mm | ||
Operating mode 2 ms: | 4,000 mm | ||
Operating mode 8 ms: | 4,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 2,500 mm | ||
Greenlight 250 µs: | 1,600 mm | ||
Highspeed 50 µs: | 1,300 mm |
At a glance
Detection of glass substrates |
Detection of solar wafers |
Indexation in FOUP for example |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Head: stainless steel, bracket: PC | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | Ø 4 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 1 mm | ||
Heat resistance: | 55 °C | ||
Ambient operating temperature: | -40 °C ... 55 °C | ||
Minimal object diameter: | 0.06 mm 1) | ||
Конструкция жилы | 151 x 0.075 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | |||
Flat housing: | - | ||
High flexible: | |||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | |||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Small 2° aperture angle | ||
Category fiber-optic cables: | 90° deflection, Flexible fiber-optic cable, LCDs/transparent objects/semiconductors | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 580 mm | ||
Operating mode 70 µs: | 1,670 mm | ||
Operating mode 250 µs: | 2,400 mm | ||
Operating mode 2 ms: | 4,000 mm | ||
Operating mode 8 ms: | 4,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 1,100 mm | ||
Greenlight 250 µs: | 700 mm | ||
Highspeed 50 µs: | 450 mm |
At a glance
Detection of glass substrates |
Detection of solar wafers |
Indexation in FOUP for example |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Head: stainless steel, bracket: PC | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | Ø 4 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 60 °C | ||
Ambient operating temperature: | -40 °C ... 60 °C | ||
Minimal object diameter: | 0.06 mm 1) | ||
Конструкция жилы | 0.75 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | |||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Small 2° aperture angle | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 570 mm | ||
Operating mode 70 µs: | 1,980 mm | ||
Operating mode 250 µs: | 2,400 mm | ||
Operating mode 2 ms: | 4,000 mm | ||
Operating mode 8 ms: | 4,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 1,000 mm | ||
Greenlight 250 µs: | 700 mm | ||
Highspeed 50 µs: | 450 mm |
At a glance
Detection of glass substrates |
Detection of solar wafers |
Indexation in FOUP for example |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Diameter, connection: | 1 mm | ||
Mounting sleeve dimension: | 20 x 1.5 x 1.7 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 10 mm | ||
Heat resistance: | 60 °C | ||
Ambient operating temperature: | -40 °C ... 60 °C | ||
Minimal object diameter: | 0.02 mm 1) | ||
Конструкция жилы | Ø 0,5 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | |||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | LCDs/transparent objects/semiconductors | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 100 mm | ||
Operating mode 70 µs: | 290 mm | ||
Operating mode 250 µs: | 500 mm | ||
Operating mode 2 ms: | 1,000 mm | ||
Operating mode 8 ms: | 1,100 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 250 mm | ||
Greenlight 250 µs: | 120 mm | ||
Highspeed 50 µs: | 120 mm |
At a glance
For installation at sites with limited space |
The smooth sleeve is simply secured by a setscrew |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Jacket: stainless steel, head: stainless steel | ||
Diameter, connection: | 1 mm | ||
Mounting sleeve dimension: | Ø 2 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 1 mm | ||
Heat resistance: | 60 °C | ||
Ambient operating temperature: | -40 °C ... 60 °C | ||
Minimal object diameter: | 0.02 mm 1) | ||
Конструкция жилы | 151 x 0.075 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | |||
90° offset: | |||
Flat housing: | - | ||
High flexible: | |||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | 90° deflection, Flexible fiber-optic cable, Smooth sleeve | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 13 mm | ||
Operating mode 70 µs: | 50 mm | ||
Operating mode 250 µs: | 85 mm | ||
Operating mode 2 ms: | 170 mm | ||
Operating mode 8 ms: | 180 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 25 mm | ||
Greenlight 250 µs: | 12 mm | ||
Highspeed 50 µs: | 12 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PC | ||
Sleeve material: | CuZn | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 100 °C | ||
Ambient operating temperature: | -40 °C ... 100 °C | ||
Minimal object diameter: | 0.2 mm 1) | ||
Конструкция жилы | Ø 1 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | |||
Sleeve: | - | ||
Suitable tip adaptor: | LL3-TA01, LL3-TA02 | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Temperature-resistant up to 100 °C | ||
Category fiber-optic cables: | Threaded sleeve, Heat-resistant | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 55 mm | ||
Operating mode 70 µs: | 180 mm | ||
Operating mode 250 µs: | 320 mm | ||
Operating mode 2 ms: | 680 mm | ||
Operating mode 8 ms: | 1,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 305 mm | ||
Greenlight 250 µs: | 50 mm | ||
Highspeed 50 µs: | 125 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PC | ||
Sleeve material: | CuZn | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | +100 °C | ||
Ambient operating temperature: | -40 °C ... +100 °C | ||
Minimal object diameter: | 0.2 mm 1) | ||
Конструкция жилы | Ø 1 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | |||
Sleeve: | - | ||
Suitable tip adaptor: | LL3-TA01, LL3-TA02 | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Temperature-resistant up to 100 °C | ||
Category fiber-optic cables: | Threaded sleeve, Heat-resistant | ||
Fiber length: | 5,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 55 mm | ||
Operating mode 70 µs: | 180 mm | ||
Operating mode 250 µs: | 320 mm | ||
Operating mode 2 ms: | 680 mm | ||
Operating mode 8 ms: | 1,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 305 mm | ||
Greenlight 250 µs: | 50 mm | ||
Highspeed 50 µs: | 125 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | FEP | ||
Core material: | Si | ||
Sleeve material: | Stainless steel 1) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 35 mm | ||
Heat resistance: | 180 °C | ||
Ambient operating temperature: | -40 °C ... 180 °C | ||
Minimal object diameter: | 0.5 mm 2) | ||
Конструкция жилы | Ø 1.5 mm | ||
Возможность обрезки волоконно-оптического кабеля 3): | |||
Thread sleeve: | |||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Temperature-resistant up to 180 ℃, large sensing range | ||
Category fiber-optic cables: | Threaded sleeve, Heat-resistant | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 230 mm | ||
Operating mode 70 µs: | 700 mm | ||
Operating mode 250 µs: | 1,300 mm | ||
Operating mode 2 ms: | 2,700 mm | ||
Operating mode 8 ms: | 4,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 620 mm | ||
Greenlight 250 µs: | 125 mm | ||
Highspeed 50 µs: | 255 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | FEP | ||
Core material: | Si | ||
Sleeve material: | Stainless steel 1) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 35 mm | ||
Heat resistance: | +180 °C | ||
Ambient operating temperature: | -40 °C ... +180 °C | ||
Minimal object diameter: | 0.5 mm 2) | ||
Конструкция жилы | Ø 1.5 mm | ||
Возможность обрезки волоконно-оптического кабеля 3): | |||
Thread sleeve: | |||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Temperature-resistant up to 180 ℃, large sensing range | ||
Category fiber-optic cables: | Threaded sleeve, Heat-resistant | ||
Fiber length: | 5,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 230 mm | ||
Operating mode 70 µs: | 700 mm | ||
Operating mode 250 µs: | 1,300 mm | ||
Operating mode 2 ms: | 2,700 mm | ||
Operating mode 8 ms: | 4,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 620 mm | ||
Greenlight 250 µs: | 125 mm | ||
Highspeed 50 µs: | 255 mm |
At a glance
For installation at sites with limited space |
The smooth sleeve is simply secured by a setscrew |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PC | ||
Diameter, connection: | 1 mm | ||
Mounting sleeve dimension: | Ø 2.5 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 10 mm | ||
Heat resistance: | 105 °C | ||
Ambient operating temperature: | -40 °C ... 105 °C | ||
Возможность обрезки волоконно-оптического кабеля 1): | |||
Thread sleeve: | - | ||
Sleeve: | |||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | 90° deflection, Smooth sleeve | ||
Fiber length: | 1,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 6 mm | ||
Operating mode 70 µs: | 19 mm | ||
Operating mode 250 µs: | 38 mm | ||
Operating mode 2 ms: | 74 mm | ||
Operating mode 8 ms: | 130 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 18 mm | ||
Greenlight 250 µs: | 11 mm | ||
Highspeed 50 µs: | 7 mm |
At a glance
Space-saving installation |
Axial cable outlet is available which prevents loops and potential damage to the cable |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | Glass | ||
Sleeve material: | Jacket: stainless steel, head: stainless steel | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | Ø 4 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 50 mm | ||
Heat resistance: | 200 °C | ||
Ambient operating temperature: | -60 °C ... 200 °C | ||
Minimal object diameter: | 0.1 mm 1) | ||
Конструкция жилы | 0.5 mm | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | 90° deflection, Heat-resistant | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 18 mm | ||
Operating mode 70 µs: | 30 mm | ||
Operating mode 250 µs: | 120 mm | ||
Operating mode 2 ms: | 220 mm | ||
Operating mode 8 ms: | 420 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 23 mm | ||
Highspeed 50 µs: | 23 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | Glass | ||
Sleeve material: | End head: stainless steel, jacket: stainless steel, head: brass | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 350 °C | ||
Ambient operating temperature: | -30 °C ... 350 °C | ||
Minimal object diameter: | 0.04 mm 1) | ||
Конструкция жилы | 1.2 mm | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Heat-resistant | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 150 mm | ||
Operating mode 70 µs: | 480 mm | ||
Operating mode 250 µs: | 790 mm | ||
Operating mode 2 ms: | 1,500 mm | ||
Operating mode 8 ms: | 1,600 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 350 mm | ||
Greenlight 250 µs: | 240 mm | ||
Highspeed 50 µs: | 140 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | Glass | ||
Sleeve material: | End head: stainless steel, jacket: stainless steel, head: brass | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | +350 °C | ||
Ambient operating temperature: | -30 °C ... +350 °C | ||
Minimal object diameter: | 0.04 mm 1) | ||
Конструкция жилы | 1.2 mm | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Heat-resistant | ||
Fiber length: | 5,000 mm | ||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 150 mm | ||
Operating mode 70 µs: | 480 mm | ||
Operating mode 250 µs: | 790 mm | ||
Operating mode 2 ms: | 1,500 mm | ||
Operating mode 8 ms: | 1,600 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 350 mm | ||
Greenlight 250 µs: | 240 mm | ||
Highspeed 50 µs: | 140 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | Glass | ||
Sleeve material: | End head: stainless steel, jacket: stainless steel, head: brass | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 350 °C | ||
Ambient operating temperature: | -30 °C ... 350 °C | ||
Minimal object diameter: | 0.04 mm 1) | ||
Конструкция жилы | 1.2 mm | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Heat-resistant | ||
Fiber length: | 3,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 150 mm | ||
Operating mode 70 µs: | 480 mm | ||
Operating mode 250 µs: | 790 mm | ||
Operating mode 2 ms: | 1,500 mm | ||
Operating mode 8 ms: | 1,600 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 350 mm | ||
Greenlight 250 µs: | 240 mm | ||
Highspeed 50 µs: | 140 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | Glass | ||
Sleeve material: | End head: stainless steel, jacket: stainless steel, head: brass | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Bend radius, end sleeve: | 10 mm | ||
Heat resistance: | 350 °C | ||
Ambient operating temperature: | -30 °C ... 350 °C | ||
Minimal object diameter: | 0.04 mm 1) | ||
Конструкция жилы | 1.2 mm | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Heat-resistant | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 140 mm | ||
Operating mode 70 µs: | 460 mm | ||
Operating mode 250 µs: | 700 mm | ||
Operating mode 2 ms: | 1,400 mm | ||
Operating mode 8 ms: | 1,500 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 350 mm | ||
Greenlight 250 µs: | 240 mm | ||
Highspeed 50 µs: | 140 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PTFE | ||
Core material: | Glass | ||
Sleeve material: | Brass (Br) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 10 mm | ||
Heat resistance: | 200 °C | ||
Ambient operating temperature: | -60 °C ... 200 °C | ||
Minimal object diameter: | 0.02 mm 1) | ||
Конструкция жилы | 0.8 mm | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Heat-resistant | ||
Fiber length: | 1,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 50 mm | ||
Operating mode 70 µs: | 180 mm | ||
Operating mode 250 µs: | 300 mm | ||
Operating mode 2 ms: | 600 mm | ||
Operating mode 8 ms: | 640 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 130 mm | ||
Greenlight 250 µs: | 80 mm | ||
Highspeed 50 µs: | 50 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | SI | ||
Core material: | Glass | ||
Sleeve material: | Brass (Br) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 200 °C | ||
Ambient operating temperature: | -60 °C ... 200 °C | ||
Minimal object diameter: | 0.04 mm 1) | ||
Конструкция жилы | 1.1 mm | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Heat-resistant | ||
Fiber length: | 1,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 130 mm | ||
Operating mode 70 µs: | 400 mm | ||
Operating mode 250 µs: | 700 mm | ||
Operating mode 2 ms: | 1,400 mm | ||
Operating mode 8 ms: | 1,500 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 320 mm | ||
Greenlight 250 µs: | 200 mm | ||
Highspeed 50 µs: | 130 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | Glass | ||
Sleeve material: | Brass (Br) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 200 °C | ||
Ambient operating temperature: | -60 °C ... 200 °C | ||
Minimal object diameter: | 0.12 mm 1) | ||
Конструкция жилы | 0.8 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Heat-resistant | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 100 mm | ||
Operating mode 70 µs: | 330 mm | ||
Operating mode 250 µs: | 570 mm | ||
Operating mode 2 ms: | 1,100 mm | ||
Operating mode 8 ms: | 1,200 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 250 mm | ||
Greenlight 250 µs: | 170 mm | ||
Highspeed 50 µs: | 100 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | Glass | ||
Sleeve material: | Brass (Br) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 200 °C | ||
Ambient operating temperature: | -60 °C ... 200 °C | ||
Minimal object diameter: | 0.12 mm 1) | ||
Конструкция жилы | 0.8 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Heat-resistant | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 100 mm | ||
Operating mode 70 µs: | 330 mm | ||
Operating mode 250 µs: | 570 mm | ||
Operating mode 2 ms: | 1,100 mm | ||
Operating mode 8 ms: | 1,200 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 250 mm | ||
Greenlight 250 µs: | 170 mm | ||
Highspeed 50 µs: | 100 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | Glass | ||
Sleeve material: | Brass (Br) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 200 °C | ||
Ambient operating temperature: | -60 °C ... 200 °C | ||
Minimal object diameter: | 0.12 mm 1) | ||
Конструкция жилы | 0.8 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Heat-resistant | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 100 mm | ||
Operating mode 70 µs: | 330 mm | ||
Operating mode 250 µs: | 570 mm | ||
Operating mode 2 ms: | 1,100 mm | ||
Operating mode 8 ms: | 1,200 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 250 mm | ||
Greenlight 250 µs: | 170 mm | ||
Highspeed 50 µs: | 100 mm |
At a glance
Space-saving installation |
Axial cable outlet is available which prevents loops and potential damage to the cable |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | Glass | ||
Sleeve material: | Brass (Br) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | Ø 3,8 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 200 °C | ||
Ambient operating temperature: | -60 °C ... 200 °C | ||
Minimal object diameter: | 0.16 mm 1) | ||
Конструкция жилы | 0.8 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | 90° deflection, Heat-resistant | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 90 mm | ||
Operating mode 70 µs: | 290 mm | ||
Operating mode 250 µs: | 480 mm | ||
Operating mode 2 ms: | 970 mm | ||
Operating mode 8 ms: | 1,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 170 mm | ||
Greenlight 250 µs: | 110 mm | ||
Highspeed 50 µs: | 75 mm |
At a glance
Space-saving installation |
Axial cable outlet is available which prevents loops and potential damage to the cable |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | Glass | ||
Sleeve material: | Brass (Br) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | Ø 3,8 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 200 °C | ||
Ambient operating temperature: | -60 °C ... 200 °C | ||
Minimal object diameter: | 0.16 mm 1) | ||
Конструкция жилы | 0.8 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | 90° deflection, Heat-resistant | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 90 mm | ||
Operating mode 70 µs: | 290 mm | ||
Operating mode 250 µs: | 480 mm | ||
Operating mode 2 ms: | 970 mm | ||
Operating mode 8 ms: | 1,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 170 mm | ||
Greenlight 250 µs: | 110 mm | ||
Highspeed 50 µs: | 75 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PFA | ||
Core material: | Si | ||
Sleeve material: | Brass (Br) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | 4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 130 °C | ||
Ambient operating temperature: | -60 °C ... 130 °C | ||
Minimal object diameter: | 0.06 mm 1) | ||
Конструкция жилы | 1.5 mm | ||
Возможность обрезки волоконно-оптического кабеля 2): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Heat-resistant | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 230 mm | ||
Operating mode 70 µs: | 690 mm | ||
Operating mode 250 µs: | 1,100 mm | ||
Operating mode 2 ms: | 2,300 mm | ||
Operating mode 8 ms: | 2,400 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 600 mm | ||
Greenlight 250 µs: | 400 mm | ||
Highspeed 50 µs: | 250 mm |
At a glance
Heat-resistant plastic and glass fiber-optic cables |
Glass fiber-optic cable with metallic sheath |
Suitable for high-temperature applications up to +350°C |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | Glass | ||
Sleeve material: | Stainless steel 1) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 300 °C | ||
Ambient operating temperature: | -40 °C ... 300 °C | ||
Minimal object diameter: | 0.2 mm 2) | ||
Конструкция жилы | Ø 1,1 mm | ||
Возможность обрезки волоконно-оптического кабеля 3): | - | ||
Thread sleeve: | |||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | |||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Temperature-resistant up to 300 °C | ||
Category fiber-optic cables: | Threaded sleeve, Heat-resistant | ||
Fiber length: | 1,000 mm |
At a glance
Quick and easy mounting |
Models with hexagonal flange for trouble-free mounting with only one nut |
Optional tip adapter for a larger detection distance and small objects |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | Stainless steel | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel | ||
Diameter, connection: | 4 mm | ||
Mounting sleeve dimension: | M4 | ||
Радиус изгиба волоконно-оптического кабеля: | 10 mm | ||
Heat resistance: | 60 °C | ||
Ambient operating temperature: | -40 °C ... 60 °C | ||
Minimal object diameter: | 0.05 mm 1) | ||
Конструкция жилы | 1.0 mm | ||
Fiber-optic cable cuttable: | - | ||
Thread sleeve: | |||
Sleeve: | - | ||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Category fiber-optic cables: | Threaded sleeve | ||
Fiber length: | 1,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 145 mm | ||
Operating mode 70 µs: | 460 mm | ||
Operating mode 250 µs: | 830 mm | ||
Operating mode 2 ms: | 1,600 mm | ||
Operating mode 8 ms: | 1,770 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 40 mm | ||
Greenlight 250 µs: | 150 mm | ||
Highspeed 50 µs: | 120 mm |
At a glance
For installation at sites with limited space |
The smooth sleeve is simply secured by a setscrew |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel 1) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | Ø 3 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 2 mm | ||
Heat resistance: | 70 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.2 mm 2) | ||
Конструкция жилы | Ø 1 mm | ||
Возможность обрезки волоконно-оптического кабеля 3): | |||
Thread sleeve: | - | ||
Sleeve: | |||
90° offset: | - | ||
Flat housing: | - | ||
High flexible: | |||
Long end sleeve: | - | ||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | Highly flexible, smooth sleeve, for moving mechanical components | ||
Category fiber-optic cables: | Flexible fiber-optic cable, Smooth sleeve | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 220 mm | ||
Operating mode 70 µs: | 650 mm | ||
Operating mode 250 µs: | 1,200 mm | ||
Operating mode 2 ms: | 2,750 mm | ||
Operating mode 8 ms: | 4,000 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 370 mm | ||
Greenlight 250 µs: | 120 mm | ||
Highspeed 50 µs: | 125 mm |
At a glance
Sensor tip can be positioned closely to the object |
Flexible end sleeve is available as an option |
Extremely narrow access to place of detection |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel 1) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | Ø 4 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 100 °C | ||
Ambient operating temperature: | -40 °C ... 100 °C | ||
Minimal object diameter: | 0.2 mm 2) | ||
Конструкция жилы | Ø 1 mm | ||
Возможность обрезки волоконно-оптического кабеля 3): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | |||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | 90° deflection integrated, maximum sensing range | ||
Category fiber-optic cables: | 90° deflection, Long end sleeve | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 180 mm | ||
Operating mode 70 µs: | 600 mm | ||
Operating mode 250 µs: | 1,100 mm | ||
Operating mode 2 ms: | 2,500 mm | ||
Operating mode 8 ms: | 3,300 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 2,050 mm | ||
Greenlight 250 µs: | 850 mm | ||
Highspeed 50 µs: | 950 mm |
At a glance
Sensor tip can be positioned closely to the object |
Flexible end sleeve is available as an option |
Extremely narrow access to place of detection |
Your benefits
Very large selection of fiber-optic cables with plastic and glass fibers, giving users more application flexibility |
Resistant to damage caused by mechanical and chemical stress, as well as high temperatures |
Standard and customer-specific types |
Simple installation saves time |
For detection of objects, surfaces, leading edges, and fluid levels |
Features | |||
Волоконно-оптические датчики: | WLL160(T), WLL170-2 / WLL170T-2, WLL180T, WLL190T-2 | ||
Тип устройства: | Fibers | ||
Jacket material: | PE | ||
Core material: | PMMA | ||
Sleeve material: | Stainless steel 1) | ||
Diameter, connection: | 2.2 mm | ||
Mounting sleeve dimension: | Ø 3 mm | ||
Радиус изгиба волоконно-оптического кабеля: | 25 mm | ||
Heat resistance: | 70 °C | ||
Ambient operating temperature: | -40 °C ... 70 °C | ||
Minimal object diameter: | 0.2 mm 2) | ||
Конструкция жилы | Ø 1 mm | ||
Возможность обрезки волоконно-оптического кабеля 3): | |||
Thread sleeve: | - | ||
Sleeve: | - | ||
90° offset: | |||
Flat housing: | - | ||
High flexible: | - | ||
Long end sleeve: | |||
Массив: | - | ||
Высокая температура: | - | ||
Oil / chemical resistent: | - | ||
ЖК / прозрачный материал/ полупроводник: | - | ||
Вакуум: | - | ||
Робототехника: | - | ||
Cветовозвращающее отражение: | - | ||
Уровень жидкости: | - | ||
Special features: | 90° deflection integrated, longest tip | ||
Category fiber-optic cables: | 90° deflection, Long end sleeve | ||
Fiber length: | 2,000 mm |
Sensing range with WLL180T | |||
Operating mode 16 µs: | 120 mm | ||
Operating mode 70 µs: | 400 mm | ||
Operating mode 250 µs: | 800 mm | ||
Operating mode 2 ms: | 1,800 mm | ||
Operating mode 8 ms: | 2,750 mm |
Sensing range with WLL170-2 | |||
Redlight 250 µs: | 325 mm | ||
Greenlight 250 µs: | 85 mm | ||
Highspeed 50 µs: | 115 mm |