The MKAS analyzer systems include all major system components like sampling probe, heated sample gas line, 1- or 2-stage gas cooler, sample gas pump, filters and valve block, depending on the stage of extension. The configuration is made according to the requirements of the application. Together with an S710 or SIDOR analyzer they fulfill also all requirements for an automatic measuring system (AMS) according to the recent EU standards. Due to their modular concept, they can be extended with additional analyzers or components. Thus, they can be adapted to a wide variety of measuring tasks.
At a glance
Up to 3 S710 or SIDOR analyzers or NOx-converter |
Includes the major system components |
Can be upgraded with optional components |
Wired and tested - ready for use |
Your benefits
Due to modular concept adaptable to the measuring task |
Proven system components offer a reliable solution |
Fulfills the requirements for an automatic measuring system according to EU standards |
Reduced response times due to sample gas bypass |
Fields of application
Measurement in raw and clean gas |
Measurement in process gases |
Emission monitoring, also according to current EU directives |
Technical data | |||
Analyzer: | S700, SIDOR | ||
Measured values: | CH4, CO, CO2, N2O, NO, NO2, O2, SO2 | ||
Comment: | Measuring ranges depend on integrated analyzer and application | ||
Gas flow rate: | With bypass pump: 0 ... 250 l/h Standard: 30 ... 60 l/h |
||
Температура процесса: | Inlet analyzer system: 0 ... +200 °C Process: 0 ... +900 °C depending on sampling probe |
||
Process gas humidity: | Dew point: ≤+65 °C | ||
Ambient temperature: | With cooling device: +5 ... +50 °C Standard: +5 ... +35 °C without direct sun exposure |
||
Ambient humidity: | 0 ... 95 % relative humidity; non-condensing |
||
Electrical safety: | CE | ||
Enclosure rating: | With cooling device: IP 34 for outer cooling circuit Standard: IP 54 |
||
Analog outputs: | Depending on analyzer and system configuration | ||
Analog inputs: | Depending on analyzer and system configuration | ||
Digital outputs: | Depending on analyzer and system configuration | ||
Digital inputs: | Depending on analyzer and system configuration | ||
Interfaces: |
depending on analyzer and system configuration |
||
Device version: | GRP cabinet Steel sheet cabinet |
||
System components: | SIDOR or S710 analyzer Analyzer cabinet Sampling probe Cooling device (option) Sample gas cooler Sample gas line Sample gas pump NOx-converter (option) |
||
Mounting: | Under roofing or other protection against exposure to direct heat radiation, high dust loads and corrosive atmospheres |